摘要
针对国华锦界电厂3号600 MW机组炉水品质长期处于非正常状态的问题,设计了相应的试验方案,从负荷变化、汽包水位、连排流量、取样管道系统等方面对该炉水品质异常变化现象进行了系统地分析。试验结果表明该机组汽包内的炉水取样系统存在问题,最后根据试验结果提出了相应的改进措施,使该问题得到顺利解决。
According to abnormal quality of boiler water in Guohua Jinjie Energy Co. Ltd. Unit 3, experiment plan was designed to analyze the abnormal changes of the boiler water quality from load changes, drum water level, continuous flow, sampling piping system, and so on. The experimental results showed that the boiler water sample had some prob- lems. According to the results corresponding measures were put forward to solve the problem.
出处
《华北电力技术》
CAS
2011年第2期41-44,共4页
North China Electric Power
关键词
汽包炉
炉水品质
汽包水位
试验
drum boiler
water quality of boiler
level of drum water
test