期刊文献+

低能质子回旋加速器内部束流测量探头的感生放射性 被引量:4

Induced radioactivity in interior beam probe for low-energy proton cyclotron
下载PDF
导出
摘要 为满足回旋加速器内部束流测量探头产生低放射性的要求,通过理论分析和蒙特卡罗模拟方法,研究了11 MeV,50μA质子束轰击铜探头产生的感生放射性,得到各种感生放射性核素的饱和放射性活度,并对结果进行了比较。分析结果表明,采用软件FLUKA进行蒙特卡罗模拟,核反应考虑完全,可同时计算不同照射时间下的直接和间接感生放射性,计算结果准确。应用该方法,质子束轰击不同测量探头产生的感生放射性可以得到详细和准确的分析和预测。 Both theoretical analysis and Monte-Carlo simulation on induced radioactivity in the copper measuring probe irradiated by proton beams with energy of 11 MeV and intensity of 50 μA have been demonstrated.Saturated activities of various kinds of radioactive nuclides obtained by these two methods were compared.The comparison indicates that the Monte-Carlo method conducted by software FLUKA can provide good simulation accuracy and complete consideration in nuclear reaction,and both the direct and indirect radioactivity under different irradiation time can be calculated simultaneously.The method can also provide accurate analysis and prediction on the induced radioactivity in different measuring probes under proton irradiation,which will provide a reference for design,exchange and disposal of the probes.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2011年第2期485-489,共5页 High Power Laser and Particle Beams
基金 中国工程物理研究院军转民开发项目
关键词 低能质子回旋加速器 感生放射性 蒙特卡罗方法 FLUKA软件 饱和放射性活度 low-energy proton cyclotron induced radioactivity Monte-Carlo method FLUKA code saturated activity
  • 相关文献

参考文献4

二级参考文献7

  • 1陆用义.低能电子加速器的感生放射性[J].南京大学学报(自然科学版),1994,30(2):247-251. 被引量:3
  • 2NCRP. Neutron Contamination from Medical Electron Accelerators [R]. Rep No. 79, NCRP, 1984.
  • 3Swanson W P. Radiological Safety Aspects of the Operation of Electron Linear Accelerators[R]. Tech Rep Series No. 188, Vienna: IAEA, 1979.
  • 4Fassò A, Sliari M, Ulrici L, et al. Predicting induced radioactivity at high-energy electron accelerators [J]. J Nucl Sci Technol (Suppl.), 2000, 827-835.
  • 5Huntzinger C J, Holmes J A. Production and control of activation products at an electron linear accelerator complex [A]. Health Phys Rad Generating Mach [C]. Reno, Nevada: the Health Physics Society, 1987.
  • 6Ferrari A, Sala P R, Fassò A, et al. FLUKA Manual (Program Verison 2002) [Z]. INFN, Italy: Istituto Nazionaledi Fisica Nucleare, 2002.
  • 7李裕熊,许炳,李珏忻,吴璨.国家同步辐射实验室感生放射性的测量和分析[J].辐射防护,1999,19(5):349-353. 被引量:13

共引文献14

同被引文献28

  • 1武祯,李君利,曾志,邱睿.电子直线加速器的感生放射性计算方法[J].清华大学学报(自然科学版),2005,45(6):813-816. 被引量:5
  • 2卢峰,刘翠杰,邓大平.加速器治疗室内感生放射性研究现状[J].国外医学(放射医学核医学分册),2005,29(6):297-300. 被引量:19
  • 3Clark D J. Beam diagnostics and instrumentation[J]. IEEE Trans on Nuclear Science j 1966 , 13(4) : 15-23.
  • 4Mackenzie G H. Beam diagnostic techniques for cyclotrons and beam lines[J], IEEE Trans on Nuclear Science ,1979,26 (2): 2312-2319.
  • 5Olivo M. Beam diagnostics equipment for cyclotrons[C]//Proceedings of the Seventh International Conference on Cyclotrons and their Ap-plications, 1975 : 331-340.
  • 6Laune B. Diagnostics for radioactive beams[C]//Proceedings of the Sixteenth International Conference on Cyclotrons and their Applications,2001: 359-363.
  • 7Patterson H W, Thomas R H. Accelerator health physics[M]. New York: Academic Press. 1973.
  • 8Swanson W P. Radiological safety aspects of the operation of electron linear accelerators[R]. IAEA Tech Rep Series No. 188, 1979.
  • 9Fasso A, Ferrari A, Ranft J, et al. FLUKA: a multi-particle transport code[R]. Yellow Report CERN-2005-010, INFN/TC_05/11,SLAC-R-773, 2005.
  • 10Battistoni G,Muraro S, Sala P R,et al. The FLUKA code: description and benchmarking[C]//Proceedings of the Hadronic Shower Simu-lation Workshop, 2006.

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部