摘要
建立了一种柱前衍生/超高效液相色谱分析方法,对一次性纸杯浸泡液中痕量甲醛进行了测定,并对衍生化条件、衍生化产物的提取条件和色谱分离条件进行了优化。该方法在0.052~2.080 mg/L范围内具有良好的线性关系,线性方程为A=37369c+267.5,线性相关系数为0.9999,检出限为0.010 mg/L(S/N=3)。采用该方法对市售的一次性纸杯浸泡液中甲醛含量进行检测,发现一次性纸杯浸泡液中甲醛含量均很低,可以安全使用。
A HPLC method was established to determine the leached trace formaldehyde in disposable paper cups using ultra performance liquid chromatography (UPLC) coupled with pre-column derivation technique. The derivation conditions, the extraction conditions of the derivative products and the chromatography conditions were optimized. The method had a good linear relationship between the range of 0.052 to 2.080 mg/L. The linear equation was A=37369c+267.5 with a linear correlation coefficient of 0,9999. The detection limit was 0.010 mg/L at the condition of S/N (signal/noise=3). Some commercially available disposable paper cups were analyzed using the method. The results showed that the disposable paper cups could be used safely, only with quite little formaldehyde leached.
出处
《广东化工》
CAS
2011年第2期161-163,共3页
Guangdong Chemical Industry
关键词
甲醛
超高效液相色谱法
一次性纸杯
formaldehyde
ultra performance liquid chromatography
disposable paper cups