基于MEMS的新型高场不对称波形离子迁移谱仪 被引量:6

High-Field Asymmetric Waveform Ion Mobility Spectrometry Based on MEMS
下载PDF
导出
摘要 简要回顾了离子迁移谱技术的发展历程,叙述了常规离子迁移谱的局限性。阐述了基于MEMS工艺的新型高场不对称波形离子迁移谱技术,该技术以物质离子的离子迁移率在高场下的非线性变化特性为基础,可实现对物质离子的空间分离。以MEMS技术为主体,自主研发了高场不对称波形离子迁移谱仪,并对挥发性有机物、苯系物、爆炸物和农药等样品进行了检测,结果表明该离子迁移谱仪能够对苯、丙酮、对二甲苯、爆炸物梯恩梯和农药硫丹等物质实现快速、高分辨和高灵敏度检测,检测精度达10-9量级,线性度达0.95。该结果展示了其在物质离子分离检测方面的巨大潜力,以及在环境、食品安全和生物大分子等领域的优越性和前景,其研究成果将推动下一代物质离子分离检测技术的发展。 The development history and shortcomings of ion mobility spectrometry(IMS)are reviewed briefly.Then,as a novel gas ion separation MEMS technology,the high-field asymmetric waveform ion mobility spectrometry(FAIMS)based on the nonlinear characteristics of ions mobility under a high-field was discussed.The acetone,benzene,TNT,paraxylene and Benzoepin were separated and detected by self-prepared FAIMS apparatus made by MEMS manufacturing technology.The results demonstrate that the five samples can be separated and detected with high efficiency,resolution and sensitivity by FAIMS.The linear regression curve of the detection current with the benzene concentration shows that the measure accuracy is 10-9 order with the linearity of 0.95.Besides that,it indicates a great promising application prospect in ion separation and detection,environment and food safety,biological macromolecules and other fields,and will promote the development of the next generation ion separation and detection technology.
出处 《微纳电子技术》 CAS 北大核心 2011年第2期112-117,共6页 Micronanoelectronic Technology
基金 国家自然科学基金资助项目(61004133 60871037) 中国科学院合肥物质科学研究院知识创新工程领域前沿项目
关键词 高场不对称波形离子迁移谱 非线性离子迁移率 微电子机械系统 离子迁移谱 快速检测 high-field asymmetric waveform ion mobility spectrometry(FAIMS) nonlinear ion mobi-lity micro-electromechanical system(MEMS) ion mobility spectrometry(IMS) rapid detection
  • 相关文献

参考文献17

  • 1SHVARTSBURG A A.Differential ion mobility spectrometry[M].Boca Raton,USA:CRC Press-Taylor & Francis Group,2009:144-146.
  • 2EICEMAN G A,SALAZAR M R,RODRIGUEZ M R,et al.Ion mobility spectrometry of hydrazine,monomethylhydrazine,and ammonia in air with 5-nonanone reagent gas[J].Analytical Chemistry,1993,65(13):1696-1702.
  • 3CLEMMER D E,JARROLD M F.Ion mobility measurements and their applications to clusters and biomolecules[J].Journal of Mass Spectrometry,1997,32(6):577-592.
  • 4HILL H H,SIEMS W F,STLOUIS R H,et al.Ion mobility spectrometry[J].Analytical Chemistry,1990,62(4):A1201-A1209.
  • 5韩海燕,贾先德,黄国栋,王鸿梅,李建权,金顺平,江海河,储焰南,周士康.同分异构体挥发性有机物的放电离子淌度谱研究[J].光谱学与光谱分析,2007,27(10):1925-1928. 被引量:3
  • 6程平,储焰南,张为俊,Patrik Spanel,David Smith.选择离子流动管质谱对汽车尾气成分的分析[J].分析化学,2004,32(1):113-118. 被引量:21
  • 7李芳,邵士勇,姚琏,李安林,李海洋.紫外离子迁移谱在线监测芳香族化合物[J].分析化学,2008,36(3):361-364. 被引量:17
  • 8BARNETT D A,PURVES R W,GUEVREMONT R.Isotope separation using high-field asymmetric waveform ion mobility spectrometry[J].Nuclear Instruments and Methods in Physics Research:A,2000,450(1):179-185.
  • 9GUEVREMONT R,BARNETT D A,PURVES R W,et al.Analysis of a tryptic digest of pig hemoglobin using ESI-FAIMS-MS[J].Analytical Chemistry,2000,72(19):4577-4584.
  • 10KRYLOV EV.Comparison of the planar and coaxial field asymmetrical waveform ion mobility spectrometer(FAIMS)[J].International Journal of Mass Spectrometry,2003,225(1):39-51.

二级参考文献72

共引文献58

同被引文献66

引证文献6

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部