摘要
混凝土外加剂与水泥相容性问题的影响因素很多,其中石膏的种类和掺量就是其中之一。以减水剂为例,其在水泥混凝土应用中存在饱和点,通过饱和点的变化可判定水泥与减水剂的相容性好坏。采用不同石膏掺量,不同高效减水剂掺量的水泥净浆试验,进行5,30,60min的净浆流动度的测试及饱和点的确定。结果表明,随着水泥中石膏含量的增加,减水剂的饱和点不断降低,饱和点时净浆流动度不断下降,水泥与减水剂的相容性越差。另外,还对石膏品种对减水剂相容性的影响进行了概要性的介绍。
There are many factors related to the adaptability between concrete addition agent and cement, and the type and adding rate of gypsum is one of them. For water reducer, there has a saturation point in the concrete application, and which decided the adaptability between cement and water reducer. Fluidity and the saturation point at 5,30,60 min of the motar which had different gypusm and water recucer adding rate were tested. The results show that with the adding of gypsum, saturation point of the water reducer decreased, and as well as the fluidity which indicated a worse adaptability. Finally, the influence of gypsum type were introduced synoptically.
出处
《水泥工程》
CAS
2011年第1期6-8,共3页
Cement Engineering
关键词
水泥
减水剂
相容性
石膏
饱和点
cement
water reducer
adaptability
gypsum
saturation