摘要
建立带有覆盖物的低温热水地板辐射盘管散热模型,利用F luent软件模拟不同覆盖物尺寸对低温热水地板辐射盘管散热的影响。研究结果表明:(1)在一定的覆盖物面积内,覆盖物面积增加造成地板局部升温。(2)在一定的覆盖物面积内,覆盖物的面积与地板的散热量减少成正比,但继续增加尺寸,其对低温热水地板辐射盘管散热的影响则不再明显。
The model of coil heat dissipation of low-temperature hot water floor radiation with the covering materials has been established,and the influences of coil heat dissipation of low-temperature hot water floor radiation at the different dimensions of covering materials were simulated.The results show that:(1) the increase of covering materials areas can cause the local floor temperature to rise at a certain extent of covering materials.(2) at a certain extent of the covering materials,the increase of covering materials areas is directly proportional to the decrease of the floor heat dissipation,but the influences of coil heat dissipation of low-temperature hot water floor radiation have not been obviously by increasing of covering materials areas.
出处
《科学技术与工程》
2011年第5期1118-1120,1124,共4页
Science Technology and Engineering
关键词
覆盖物
热水地板辐射采暖
盘管
散热
数值模拟
covering materials hot water floor radiation heating coil heat dissipation numerical simulation