新型遮阳系统对太阳散射辐射的遮阳效果研究 被引量:4

RESEARCH ON THE SHADING EFFECT FOR SOLAR DIFFUSE RADIATION THROUGH THE NEW SHADING SYSTEM
下载PDF
导出
摘要 通过搭建室外太阳散射辐射得热量的测量装置,对透过遮阳系统进入室内的太阳散射辐射得热量进行了试验研究,并通过建立理论模型对测试结果进行了验证分析,结果表明:该实验装置对透过遮阳系统的太阳散射辐射得热量的测试是可行的,同时通过试验得到了该遮阳系统对太阳散射辐射的遮阳效果。 The shading system was widely used as an energy efficiency technology in the hot summer and cold winter area. The solar radiation through the shading system generally consists of the direct radiation and the diffuse radiation. The new shading system--intelligent shading system shade most direct radiation and the most diffuse radiation can reach the indoor space. One outdoor test facility which was used to measure the diffuse radiation through the shading system was present- ed. The research on the diffuse radiation was carried on. The numerical model was built and the experimental result was validated. Many experimental data proved the test facility can be used to measure the diffuse radiation. The shading effect for solar diffuse radiation of the new shading system was carried through the experiment.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2011年第1期95-100,共6页 Acta Energiae Solaris Sinica
基金 国家"十一五"科技支撑计划项目(2008BAJ12B05)
关键词 太阳散射辐射 遮阳 模拟 测试 solar diffuse radiation shading simulation test
  • 相关文献

参考文献13

  • 1Klems J H. Net energy performance measurements on electro- chromic skylights[J]. Energy and Buildings, 2001, 33(2): 93-102.
  • 2Klems J H. A new method for predicting the solar heat gain of complex fenestration systems: I. Overview and derivation of the matrix layer calculation[J]. ASHRAE Trans, 1994, 100(1) : 1065-1072.
  • 3Klems J H. A new method for predicting the solar heat gain of complex fenestration systems: II. Detailed description of the matrix layer calculation[J]. ASHRAE Trans, 1994, 100 (1): 1073-1086.
  • 4Klems J H, Kelley G O. Calorimetric measurements of inward- flowing fraction for complex glazing and shading systems [ J ]. ASHRAE Trans, 1996, 102( 1 ) : 947-954.
  • 5Klems J H, Warner J L. A comparison between calculated and measured SHGC for complex glazing systems[J]. ASHRAE Trans, 1996, 102(1) : 931-939.
  • 6Pfrommer P, Lomas K J, Kupke Chr. Solar radiation trans- port through slat-type blinds: A new model and its application for thermal simulation of buildings[J]. Solar Energy, 1996, 52(2) : 77-91.
  • 7Hans Simmder, Bruno Binder. Experimental and numerical determination of the total solar energy transmittance of glazing with Venetian blind shading[J]. Building and Environments, 2008, 43(2) : 197-204.
  • 8Breitenbach J, Lart S, LaEngle I, et al. Optical and thermal performance of glazing with integral venetian blinds[ J]. En- ergy and Buildings, 2001, 33(5): 433-442.
  • 9Tzempelikos Athanassios, Athienitis Andreas K. The impact of shading design and control on building cooling and lighting demand[J]. Solar Energy, 2007, 81(3): 369-382.
  • 10曹国庆,涂光备,杨斌.水平遮阳方式在住宅建筑南窗遮阳应用上的探讨[J].太阳能学报,2006,27(1):96-100. 被引量:32

二级参考文献5

共引文献119

同被引文献25

  • 1杨慧媛,高甫生.玻璃类型对玻璃幕墙建筑室内热环境的影响分析[J].暖通空调,2005,35(10):23-28. 被引量:13
  • 2曹国庆,涂光备,杨斌.水平遮阳方式在住宅建筑南窗遮阳应用上的探讨[J].太阳能学报,2006,27(1):96-100. 被引量:32
  • 3GB/T 2680-1994,建筑玻璃可见光透射比、太阳光直接透射比、太阳能总透射比、紫外线透射比及有关窗玻璃参数的测定[S].
  • 4Klems J H. A new method for predicting the solar heat gain of com- plex fenestration systems:I. Overview and derivation of the matrix layer calculation [ J ]. ASHRAE Trans, 1994,100 : 1065-1072.
  • 5Klems J H. A new method for predicting the solar heat gain of com- plex fenestration systems:II. Detailed description of the matrix lay- er calculation [ J ]. ASHRAE Trans, 1994,100 : 1073-1086.
  • 6Klems J H, Kelley G O. Calorimetric measurements of inward-flow- ing fraction for complex glazing and shading systems [ J ]. ASHRAE Trans, 1996,102:947-954.
  • 7Hans Simmler, Bruno Binder. Experimental and numerical determi- nation of the total solar energy transmittance of glazing with Vene- tian blind shading[ J ]. Building and Environments, 2008,43 (2) : 197 -204.
  • 8JG/T281--2010建筑遮阳产品隔热性能试验方法[s].
  • 9王一飞,由世俊,解勇,刘月莉.窗太阳得热系数测试设备的研发[J].太阳能学报,2009,30(8):1028-1032. 被引量:3
  • 10田慧峰,孙大明,周海珠.建筑节能65%中活动外遮阳的贡献率[J].墙材革新与建筑节能,2009(10):48-50. 被引量:8

引证文献4

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部