目的了解TORCH-IgM抗体检测方法的优缺点。方法于2010年5月至2010年6月期间来我科室进行产前检查的孕妇123例抽取血样,采用酶联免疫吸附试验(enzyme-linked immunosorbent assay,ELISA)、微粒子酶免疫法(microparticle enzyme immunoassay,MEIA)和胶体金免疫层析法(gold immunochromat ographic assay,GICA)分别检测TORCH-IgM抗体,并进行分析比较,以找出适合临床应用的筛查方法。结果 ELISA法、MEIA法和GICA法检测TORCH-IgM的阳性率见下表。结论 ELISA法、MEIA法和GICA法检测TORCH-IgM抗体阳性检出率之间的差别均无统计学意义(P>0.05)。
Objective: To realize merits and faults of TORCH-IgM antibodies detective methods.Methods: We sampled the blood of 123 pregnant women who took the routine gestational examine come to my department from 2010 May to 2010 June.We used Enzyme-linked immunoabsorbent assay (ELISA) ,microparticle enzyme immunoassay (MEIA) and gold immunochromat ographic assay (GICA) to detect IgM antibodies of TORCH,then analysis and comparison to find screen way for clinical application.Results: ELISA、MEIA and GICA detect positive rates of IgM antibodies of TORCH were as follow tabulation.Conclusion: It isnot statistic meaning to detect positive rates of IgM antibodies of TORCH with ELISA、MEIA and GICA.