PET/CT衰减系数转换方法对标准摄取值测量的影响研究 被引量:1

Effect of Different Attenuation Coefficient Transformation Algorithms on PET/CT SUV Measurement
原文传递
导出
摘要 目的研究两种不同的衰减系数转换方法对正电子发射计算机断层显像/计算机体层扫描(PET/CT)标准摄取值(SUV)测量值的影响。方法 2009年11-12月,从经过PET/CT氟代脱氧葡萄糖(FDG)显像患者中选取20例,其口腔中均有金属假牙。以四段转换法和二段转换法重建全身衰减校正断层图像。分别选取3种高密度区域和7种低密度区域,测量其最大SUV和平均SUV,比较两种转换方法SUV测量值。结果平均SUV:二段转换法的3种高密度区域SUV降低,在7种低密度区域中,1种区域增高,1种区域降低(P值均<0.05)。最大SUV:二段转换法的2种高密度区域的SUV降低,在7种低密度区域中,1种区域增高,2种靠近高密度组织的区域降低(P值均<0.05)。结论二段转换法能降低高密度区域的SUV,可用于减小体内金属植入物和CT对比剂造成的过度校正。 Objective To explore the effect of two attenuation correction algorithms on PET/CT SUV measurement.Methods From November to December 2009,the PET Slice of 20patients with metallic dental implant were reconstructed with four-and two-section algorithms respectively.Mean SUV and maximum SUV were measured in three high-density areas and 7low-density areas.Paired t test were performed to compare the differences.Results Mean SUV:two-section algorithm produced significantly lower SUV in all the three high-density areas;in the 7low-density areas,SUV increased obviously in one area and decreased apparently in one area(P0.05).Maximum SUV: two-section algorithm produced significantly lower SUV in two high-density areas,SUV increased obviously in one area and decreased apparently in two areas which was adjacent to the high density areas(P0.05).Conclusion Two-section algorithm produces lower SUV measurement value than the four-section algorithm does,and it is useful in PET/CT studies for patients with metallic dental implant and when CT contrast is used.
出处 《华西医学》 CAS 2010年第11期2052-2054,共3页 West China Medical Journal
关键词 PET/CT 标准摄取值 衰减系数 PET/CT Standerd uptake Attenuation coefficient
  • 相关文献

参考文献8

  • 1Kamel EM,Burger C, Buck A, et al. Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner[J]. Eur Radiol, 2003,13 (4) : 724-728.
  • 2Beyer T,Kinahan PE,Townsend DW,et al. The use of X-ray CT for attenuation correction of PET data// In Proceedings of the 1994 IEEE Nuclear Science Symposium and Medical Imaging Conference, Trendler RC[C]. Norfolk, VA, USA, 1994: 1573-1577.
  • 3Kinahan PE, Hasegawa BH, Beyer T. Xray-based attenuation correction for positron emission tomography/computed tomography scanners[J]. Semin Nucl Med, 2003,33 (6) : 166-179.
  • 4Kinahan PE, Townsend DW, Beyer T, et al. Attenuation correction for a combined 3D PET/CT scanner [J]. Med Phys, 1998,25(10) :2046-2053.
  • 5Bai C,Shao L, Da Silva AJ, et al. A generalized model for the conversion from CT numbers to linear attenuation coefficients[J]. IEEE Trans Nucl Sci,2003,50(5) :1510-1515.
  • 6Guy MJ,Castellano-Smith IA, Flower MA, et al. DETECT-dual energy transmission estimation CT-for improved attenuation correction in SPECT and PET[J].IEEE Trans Nucl Sci, 1998(6), 45:1261-1267.
  • 7Bai C, Tung C, Kolthammer J, et al. CT based attenuation correction in PET image reconstruction for the Gemini system[J]. IEEE Nuclear Science Symposium Conference Record, 2003, (5) : 3082-3086.
  • 8Nakae Y, Sakamoto K, Minamoto T, et al. Clinical evaluation of a newly developed method for avoiding artifacts caused by dental fillings on X ray CT[J]. Radiol Phys Technol, 2008(1): 115-122.

同被引文献11

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部