Monaco治疗计划系统中参数设置对容积旋转调强放射治疗计划质量的影响 被引量:6

Impacts of Parameter Settings on the Quality of Plans for the Volumetric Modulated Arc Therapy with Monaco Treatment Planning System
原文传递
导出
摘要 目的研究Monaco治疗计划系统中不同参数设置对容积旋转调强放射治疗(VMAT)计划质量的影响,得出更合理的治疗计划参数设置以提高VMAT治疗质量。方法 2010年15月间治疗3例患者,为食管癌、宫颈癌和鼻咽癌各1例,分别设置不同的计划参数进行容积旋转调强计划优化,通过多种评估指标比较各VMAT计划质量的差异,得出临床所需的MSC、MSS、SSF、Sm、MMS和MDR共6个治疗计划参数对VMAT治疗质量的影响。结果 MSC、MSS和SSF的3个参数对VMAT治疗质量不产生影响,有影响的Sm、MMS和MDR参数中,随着Sm和MMS值的增大,VMAT计划的剂量分布逐渐变差,但控制点数、机器跳数和照射时间均逐渐减小;随着MDR值增大,VMAT治疗的剂量分布先逐渐变差后不变,控制点数和机器跳数均是先增大后不变,而照射时间是先减小后不变。结论 Sm、MMS和MDR3个参数对VMAT计划质量有较大影响,对不同的患者,设置合适的Sm、MMS和MDR值对提高计划质量非常重要。 Objective To investigate the impacts of p ar ameter settings on the quality of plans for the volumetric modulated arc therapy (VMAT) with Monaco treatment planning system. Methods Three p atients who underwent VMAT from January to May 2010 were selected. The planning optimizations were processed by setting different planning parameters, including MSC, MSS, SSF, Sm, MMS and MDR, respectively. Then the quality of each plan with a certain set of parameters was evaluated by various evaluation indexe s. The differences of quality among different plans were analyzed by comparing t hese indexes. Results There was no influence on the quality of VMAT planning for the parameter MSC, MSS and SSF to be set with differen t values. However, the other three parameters, MSC, MSS and SSF, affecte d the quality of VMAT planning with different values. Along with the aggrandizem ent of Sm and MMS value, the dose distribution of VMAT plans gradually b ecame bad, while the number of control points, machine monitor units and irradia tion time were gradually reduced. And along with the aggrandizement of MDR v alue, the dose distribution of VMAT plans became bad gradually until a constant state was reached, and both the number of control points and machine monitor uni ts increased at first and then kept constant, while irradiation time decreased a t first and then kept constant. Conclusion The selections of pa rameter Sm, MMS and MDR impact the quality of VMAT planning greatly. It is very important to set the suitable value of Sm, MMS and MDR to get th e best planning quality for patients with different complexity.
出处 《华西医学》 CAS 2010年第12期2133-2137,共5页 West China Medical Journal
关键词 容积旋转调强放疗 计划优化 计划参数 计划质量 Volumetric modulated arc therapy Planning optimization Planning parameter Planning quality
  • 相关文献

参考文献11

  • 1Otto K. Volumetric modulated arc therapy: IMRT in a single gantry arc[J].Med Phys, 2008, 35(1) : 310-317.
  • 2Webb S. The physical basis of IMRT and inverse planning[J]. Br J Radiol, 2003, 76(10): 678-689.
  • 3Vanetti E, Clivio A, Nicolini G, et al. Volumetric modulated arc radiotherapy for carcinomas of the oro-pharynx, hypopharynx and larynx: a treatment planning comparison with fixed field IMRT[J].Radiother Oncol, 2009, 92(1): 111-117.
  • 4Verbakel WF, Senan S, Cuijpers JP, et al. Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity modulated arcs[J].Radiother Oncol, 2009, 93(2): 122-124.
  • 5Bortfeld T, Webb S. Single-arc IMRT? [J]. Phys Med Biol, 2009, 54:9 -20.
  • 6Fippel M. Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm[J].Med Phys, 1999, 26 (8): 1466-1475.
  • 7Fippel M, Laub W, Huber B, et al. Experimentel investigation of a fast Monte Carlo photon beam dose calculation algorithm [J]. Phys Med Biol, 1999, 44(12): 3039-3054.
  • 8Feuvret L, Noel G, Mazeron JJ, et al. Conformity index: a review[J].Int J Radiat Oncol Biol Phys, 2006, 64 (2): 333-342.
  • 9Bertelsen A, Hansen CR, Johansen J, et al. Single Arc Volumetric Modulated Arc Therapy of head and neck cancer[J].Radiother Oncol, 2010, 95(2): 142-148.
  • 10Alber M, Nusslin F. An objective function for radiation treatment optimization based on local biological measures[J]. Phys Med Biol, 1999, 44(2): 479-493.

同被引文献64

  • 1曹彦坤,迟子锋,焦广青,刘丹,李润霄,韩春.食管癌IMRT计划设计降低子野数及MU数方法研究[J].中国医学物理学杂志,2011,28(2):2460-2463. 被引量:10
  • 2赵充,卢泰祥,韩非,卢丽霞,黄劭敏,邓小武,林承光,崔念基.139例鼻咽癌调强放疗的临床研究[J].中华放射肿瘤学杂志,2006,15(1):1-6. 被引量:154
  • 3蔡勇,何玉香,韩树奎,吴昊,弓健,徐博.直肠癌盆腔常规放疗与三维适形放疗的剂量学研究[J].中华放射肿瘤学杂志,2007,16(3):201-205. 被引量:20
  • 4Bedford JL. Treatment planning for volumetric modulated arc ther- apy [J]. MedPhys, 2009, 36(11) :5128-5138.
  • 5Yu CX, Tang G. Intensity-modulated arc therapy: principles, technologies and clinical implementation [ J ]. Phys Med Biol, 2011, 56(5) :R31-R54.
  • 6Bzdusek K, Friberger H, Eriksson K, et al. Development and e- valuation of an efficient approach to volumetric arc therapy plan- ning [Jl. Med Phys, 2009, 36(6):2328-2339.
  • 7Feuvret L, Noel G, Mazeron JJ, et al. Conformity index: a review [J]. Int J Radiat Oncol Biol Phys, 2006, 64(2) :333-342.
  • 8ICRU. International Commission on Radiation Units and Measure- ments. Prescribing, recording, and reporting photon-beam intensi- ty-modulated radiation therapy (IMRT). ICRU Report 83 [ J ]. Journal of the ICRU, 2010, 10( 1 ) : 1-106.
  • 9Lee TF, Chao PJ, Ting HM, et al. Comparative analysis of Smart- Arc -based dual arc volumetric -modulated arc radiotherapy (VMAT) versus intensity-modulated radiotherapy (IMRT) for na- sopharyngeal carcinoma [ J ]. Appl Clin Med Phys,2011,12 ( 4 ) : 158-165.
  • 10Lu SH, Cheng JC, Kuo SH, et al apy for nasopharyngeal carcinoma TomoTherapy and step-and-shoot 2012, Available online. Volumetric modulated arc ther- a dosimetric comparison with IMRT [ J ]. Radiother Oncol,.

引证文献6

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部