摘要 搭建了自然循环平板式太阳能热水器(NFSWH)的实验平台,根据太阳能热水器国家测试标准方法对系统的热效率进行测试。用TRNSYS软件建立了NFSWH的瞬态模型。模拟和实际测量了水箱放置高度对热水器热效率的影响。结果显示,实验与模拟吻合较好。对于集热面积为1.5m2水箱容积为120L的系统,水箱底到集热器出口的高度(Hr)为0.74m时,系统的热效率最大(67.7%).放置高度为0.44-1.04m时,系统集热效率变化不大,在3%以内。 The device of natural circulation flat plate solar water heater has been built.In accordance with the national testing standard methods,the efficiency of the system was tested.The transient model of NFSWH has been developed by using the TRNSYS simulation program.The effect of installation height between the bottom of the tank and the outlet of the collector on efficiency of the solar collector has been investigated both theoretically and experimentally.The data show the theoretical results are highly consistent with the experimental ones.Results indicate that the optimum value of installation height is 0.74m with the maximum efficiency of 67.5% for the system with a total area of 1.5m2 and a storage water tank capacity of 120L.When the installation height is between 0.44 and 1.04 m,the change of thermal efficiency of the solar system is at a range of 3%.
出处 《云南师范大学学报(自然科学版)》 2011年第1期40-43,58,共5页 Journal of Yunnan Normal University:Natural Sciences Edition
基金 国家自然科学基金资助项目(50966004) 高等学校博士学科点专项科研基金资助项目(20095303110001) 云南省科技计划资助项目(2007C0016Z 2008CA024 2008GA014) 教育部长江学者和创新团队发展计划资助
关键词 太阳能热水器 自然循环 水箱放置高度 热效率 TRNSYS Solar water heater Natural circulation Installation height Thermal performance TRNSYS
  • 相关文献

参考文献10

  • 1AFIF H.Thermosyphon solar water heaters:effect of storage tank volume and configuration on efficiency[J].Energy Conversion and Management,1997,38(9):847 -854.
  • 2SHARIAH A M,G LOF G.The optimization of tankvolume-to-collector-area ratio for a thermosyphon solar water heater[J].Renewable Energy.1996,7 (3):289-300.
  • 3SHARIAH A M,HITILE D C,G LOF G.Computer simulation and optimization of design parameters for thermosyphon solar water heater[C].ASME Int.Solar Energy Conf.San Francisco,CA,USA,27-30March 1994,393-399.
  • 4刘群生,张勇,高文峰,刘滔.自然循环平板式太阳能热水系统的设计计算[J].能源工程,2001,21(5):5-8. 被引量:4
  • 5高靖平,王书清.家用循环式太阳能热水器水箱高度差的分析计算[J].山东能源,1992(1):9-13. 被引量:1
  • 6Solar Energy Laboratory,University of Wisconsin Madison.TRNSYSI6,a transient simulation program user's manual[J].2007,(5):321 -324.
  • 7DUFFIE J A,BECKMAN W A.Solar Engineering of Thermal Processes[M].Wiley.NewYork.1991.
  • 8MORRISON G L,BRAUN J E.System modeling and operation characteristics of thermosyphon solar water heaters[J].Solar Energy,1985,34(4 -5):389 -405.
  • 9程艳斌,何官兴,唐润生.倾斜面上直射辐射计算方法的探讨[J].云南师范大学学报(自然科学版),2009,29(2):49-53. 被引量:6
  • 10韩雷涛,苏庆益,夏朝凤,谢建.节能建筑技术经济评价方法分析[J].云南师范大学学报(自然科学版),2008,28(1):37-42. 被引量:8

二级参考文献16

  • 1缪启龙,周锁铨,吴息,曾宪宁.西部山区总辐射气候学计算及分布[J].南京气象学院学报,1994,17(2):177-182. 被引量:29
  • 2袁莹,苏粤.太阳热水器与建筑一体化设计[J].华中建筑,2005,23(1):89-91. 被引量:20
  • 3王炳忠 张富国 李立贤.我国太阳能的资源及其计算.太阳能学报,1980,1(1):1-9.
  • 4Liu BYH and Jordan RC. Daily insolation on surface tilted toward the equator[ J]. ASHRAE Journal 1962, 3/10:53 -56.
  • 5John A Duffle, William A Beckman. Solar Engineering of Thermal Processes[ M ]. John Wiley & Sons, Inc, 1980,62 -98.
  • 6Rabl A. Active solar collectors and their applications [ M ], Oxford: Oxford University Press, 1981.
  • 7韩雷涛,谢建,夏朝凤,苏庆益,吴茂刚.昆明市太阳热水装置利用的效益分析[J].云南师范大学学报(自然科学版),2007,27(5):39-42. 被引量:3
  • 8陆维德 过慧芬 孙孝兰.自然循环太阳能热水系统的设计研究[J].太阳能学报,1981,2(1):22-32.
  • 9J.A达菲,W.A贝克曼.太阳能-热能转换过程[M].北京:科学出版社,1980.
  • 10唐润生 吕恩荣.集热器最佳倾角的选择.太阳能学报,1988,9(4):269-375.

共引文献15

同被引文献69

  • 1卢川,张勇,鲁剑超,董化平.基于CFD方法的自然循环反应堆冷却剂流动特性分析[J].核动力工程,2012,33(S1):111-114. 被引量:5
  • 2班婷,朱明,王海.太阳能集热器的研制及结构优化[J].农业工程学报,2011,27(S1):277-281. 被引量:35
  • 3黄代顺,蒋孝蔚,余红星.非能动安全壳冷却系统CFD冷凝和蒸发模型研究[J].核动力工程,2013,34(S1):188-191. 被引量:7
  • 4彭斯亮,侯玉林.自然循环余热锅炉的安装[J].能源与节能,2014,0(2):143-144. 被引量:2
  • 5阎昌琪,曹夏听.核反应堆安全传热[M].哈尔滨:哈尔滨工程大学出版社,2010.
  • 6AFIFH. Thermosyphon solar water heaters:effect of storage tank vol-ume and configuration on efficiency[J].Energy Conversion and Manage-ment,1997,(09):847-854.
  • 7秦立新.新一代"水下幽灵"若隐若现[N].解放军报,2013-05-02.
  • 8Sun L, Sun L C, Yan C Q, et al. Conceptual Design and Analysis of a Passive Residual Heat Removal System for a 10MW Molten Salt Reactor Experiment [ J ]. Progress in Nuclear Energy ,2014,70 ( 11 ) : 149 -158.
  • 9Min B Y, Park H S, Shin Y C, et al. Experimental Verification on the Integrity and Performance of the Passive Residual Heat Removal System for a SMART Design with VISTA-ITL[ J ]. Annals of Nuclear Ener- gy,2014,71 (9) :118 - 124.
  • 10Nitin M, Jyeshtharaj B J, Arun K N, et al. Numerical Investigation of Three-dimensional Natural Circulation Phenomenon in Passive Safety Systems for Decay Heat Removal in Large Pools [ J ]. International Journal of Heat and Mass Transfer,2015,81 ( 2 ) :659 - 680.

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部