摘要 目的 为了使血泵驱动器能够根据患者的生理需求调节血泵输出,提出基于心率的自适应血泵控制算法,该算法得出的算法流量能随着生理需求而变化.方法 基于心率与心输出量之间的关系,将血泵输出流量设计成为心率的函数,根据文献中提供的正常人体心率与心输出量的数据,利用最小二乘法求得算法中的常量系数.为验证算法的准确性,计算出根据算法所得到的血泵输出流量与正常人体自然心脏心输出量之间的最大误差和相关系数.结果 当心率为75次/min时,根据上述算法得到的流量能达到5.01L/min;在50~120次/min心率范围内,算法中流量会随着心率的提高而增大;算法流量与自然心脏心输出量的相对误差为1%,相关系数为0.997.结论 以上结果表明,该算法可以根据受试者的血液需求量自动调整血泵工作状态. Objective In order to regulate the blood pump responsing to the demand of patient' s cardio output, we proposed an adaptive blood pump control algorithm based on heart rate, so that the blood flow derived from the algorithm varies with the physiological needs. Methods Based on the relationship between heart rate and cardiac output, the algorithm was designed as a function of the heart rate. According to the data of heart rate and cardiac output derived from literatures, the constant coefficients were obtained through the least squares algorithm. To verify the accuracy of the algorithm, we calculated the maximum error and the correlation coefficient between the pump flow and cardiac output. Results With the algorithm,, the blood pump flow rate was 5.01L/min when heart rate of 75 beats/min, and the blood pump flow rate gradually became larger with the increase of heart rate within heart rate range from 50 to 120 times / min. The relative error between blood pump flow rate obtained from algorithm and cardiac output was 1%. Conclusion These results suggest that the algorithm for controlling blood pump flow rate regulate the pump in response to the demand of patient's cardio output.
出处 《北京生物医学工程》 2011年第1期89-91,共3页 Beijing Biomedical Engineering
基金 北京工业大学项目(31500054R5001) 国家学术工作人才小组培训项目(01500054R8001) 国家自然科学基金(11072012)资助
关键词 血泵 心率 流量 心输出量 blood pump heart rate flow rate cardiac output
  • 相关文献

参考文献9

  • 1Fu MH.Development and Evaluation of a Robust and Intelligent Digital Control System for a Rotary Blood Pump[D].Columbus:The Ohio State university,1998.
  • 2Esmore D,Rosenfeldt FL.Mechanical circulatory support for the failing heart:past,present and future[J].Heart Lung and Circulation,2005,14:163-166.
  • 3Karantonis DM,Lovell NH,Ayre PJ,et al.Classification of physiologically significant pumping states in an implantable rotary blood pump:Effects of cardiac rhythm disturbances[J].Artif Organs,2007,6 (31):476-479.
  • 4万峰,王京生.现代心力衰竭外科治疗学[M].北京:中国协和医科大学出版社,2007:32-47.
  • 5陆柳,李景锡.心率对每搏输出量和心输出量影响的讨论[J].中国医学物理学杂志,2002,19(4):237-238. 被引量:21
  • 6Finocchiaro T,Heinke S,et al.Methods of design,simulation,and control for the development of new VAD/TAH concepts[J].Biomed Tech,2009,54 (5):269-281.
  • 7Nakata K,Yosikawa M,Takano T,et al.Estimation of pump flow rate and abnormal condition of implantable rotary blood pumps during long-term in vivo study[J].Artif Organs,2000,4(24):315-319.
  • 8Buchner T,Zebrowski JJ,Gielerak G,et al.Direction of information flow Between heart rate,Blood Pressure and Breathing.Dept Phys,Calcutta,INDIA,FEB:International Workshop on Complex Dynamics of Physiological Systems Presidency Coll,2007:33-47.
  • 9Vollkron M,Schima H,Huber L,et al.Control of Implantable Axial blood pumps based on physiological demand[C].Minneapolis,Minnesota,USA:Proceedings of the 2006 American Control Conference,2006.

二级参考文献3

  • 1李景锡.左心室每博输出量的估算[C].中国医药卫生学术文库(第二辑).北京:科学技术文献出版社,1997.1894-1895.
  • 2Weissler AM, Harris WS and Sehoenfeld CD. Systolic time in intervals in heart failure in man[J]. Circulation,1968,37:149-153.
  • 3Willems JL, Roeldandt JG and et al. The left ventricular ejection time in elderly subjects[J]. Circulation, 1970,42:37-40.

共引文献20

同被引文献5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部