期刊文献+

Corrosion risk assessment of chloride-contaminated concrete structures using embeddable multi-cell sensor system 被引量:2

Corrosion risk assessment of chloride-contaminated concrete structures using embeddable multi-cell sensor system
下载PDF
导出
摘要 Monitoring the service condition of concrete structures requires the quantitative assessment of properties and corrosion rate of structural steels surrounded by concrete.A multi-cell sensor system that included a reference electrode,a chloride content sensor,a macrocell current unit and an electrical resistance measurement unit was developed.This system provided the following important electrochemical data in the cover-zone concrete on site:open circuit potential,macrocell current from anodes to cathode,chloride profile,concrete resistance and corrosion rate of built-in anodes.The experimental results show that the macrocell current increases when the chloride content in concrete is higher.Thus,monitoring the chloride content is a good method for monitoring the corrosion state.The chloride ion content and cover depth are the key factors that affect the electrical resistance of concrete.Without considering the temperature and time,a simplified model of the instantaneous corrosion rate of steel rebar in a concrete structure based on the measured chloride contents and concrete resistance was proposed.The test results further prove the reliability of this simplified predicting model. Monitoring the service condition of concrete structures requires the quantitative assessment of properties and corrosion rate of structural steels surrounded by concrete. A multi-cell sensor system that included a reference electrode, a chloride content sensor, a macrocell current unit and an electrical resistance measurement unit was developed. This system provided the following important electrochemical data in the cover-zone concrete on site: open circuit potential, macrocell current from anodes to cathode, chloride profile, concrete resistance and corrosion rate of built-in anodes. The experimental results show that the macrocell current increases when the chloride content in concrete is higher. Thus, monitoring the chloride content is a good method for monitoring the corrosion state. The chloride ion content and cover depth are the key factors that affect the electrical resistance of concrete. Without considering the temperature and time, a simplified model of the instantaneous corrosion rate of steel rebar in a concrete structure based on the measured chloride contents and concrete resistance was proposed. The test results further prove the reliability of this simplified predicting model.
作者 卢爽 巴恒静
出处 《Journal of Central South University》 SCIE EI CAS 2011年第1期230-237,共8页 中南大学学报(英文版)
基金 Project(200632800003-11) supported by Western Communications Construction Scientific and Technological Project in China
关键词 混凝土结构 传感器系统 氯离子腐蚀 多细胞 风险评估 氯离子含量 嵌入 污染 concrete structures corrosion rate resistance chloride content macrocell current multi-cell sensor
  • 相关文献

参考文献30

  • 1VERA R,VILLARROEL M,CARVAJAL A M,VERA E,ORTIZ C.Corrosion products of reinforcement in concrete in marine and industrial environments[J].Materials Chemistry and Physics,2009,114(1):467-474.
  • 2SOLEYMANI H R,ISMAIL M E.Comparing corrosionmeasurement methods to assess the corrosion activity of laboratory OPC and HPC concrete specimens[J].Cement and Concrete Research,2004,34(11):2037-2044.
  • 3McCARTER W J,VENNESLAND (φ).Sensor system for use in reinforced concrete structures[J].Construction and Building Materials,2004,18(6):351-358.
  • 4XU Jin-xia,JIANG Lin-hua,WANG Jing-xiang.Influence of detection methods on chloride thresthold value for the corrosion of steel reinforcement[J].Construction and Building Materials,2009,23(5):1902-1908.
  • 5BASHEER P A M,GILLEECE P R V,LONG A E,McCARTER W J.Monitoring electrical resistance of concretes containing alternative cementitious materials to assess their resistance to chloride penetration[J].Cement & Concrete Composites,2002,24(5):437-449.
  • 6MONTEMOR M E,ALVES J H,sIMOES A M,FERNANDES J C S,LOURENCO Z,COSTA A J S,APPLETON A J,FERREIRA M G S.Multiprobe chloride sensor for in situ monitoring of reinforced concrete structures[J].Cement & Concrete Composites,2006,28(3):233-236.
  • 7de VERA G,CLIMENT M A,ANTON C,HIDALGO A,ANDRADE C.Determination of the selectivity coefficient of a chloride ion selective electrode in alkaline media simulating the cement paste pore solution[J].Journal of Electruanalytieal Chemistry,2010(1/2):43-49.
  • 8HANSSON C M,POURSAEE A,LAURENT A.Macrocell and microcell corrosion of steel in ordinary Portland cement and high performance concretes[J].Cement and Concrete Research,2006,36(11):2098-2102.
  • 9SCHIEBL R M.Macrocell sensor systems for monitoring of the corrosion risk of the reinforcement in concrete structures[J].NDT&E International,2001,34(6):435-442.
  • 10ELSENER B.Macrocell corrosion of steel in concrete-implications for corrosion monitoring[J].Cement & Concrete Composites,2002,24(1):65-72.

同被引文献8

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部