期刊文献+

基于灰度差异与自相关的粒子速度测量新方法 被引量:1

New method for measuring particle velocity based on gray scale difference and autocorrelation
下载PDF
导出
摘要 基于曝光时间差异对应不同的粒子像点灰度的原理,提出了一种基于灰度差异与自相关的粒子速度测量方法。介绍了实现测量的流程和图像处理软件的算法。通过数值模拟和测量实验,验证了所提出的图像处理过程及算法的可行性,可实现流场中多数示踪粒子各自对应速度量的测量。 A new method for measuring the particle velocity based on the gray scale difference and the autocorrelation was proposed from the fact that different exposure time corresponds to different gray scale of particle image point. The flow chart of measuring process and the software algorithm for the image processing were introduced. The numerical simulation and measuring experiment were done and the feasibility Of the image processing and its algorithm were validated, showing possibility of simultaneously measuring the velocities of many tracer particles in a flow field.
出处 《吉林大学学报(工学版)》 EI CAS CSCD 北大核心 2011年第2期563-568,共6页 Journal of Jilin University:Engineering and Technology Edition
基金 国家自然科学基金项目(50676055) 上海市青年科技启明星计划项目(07QA14055)
关键词 激光光学 灰度差异 自相关 粒子图像 速度测量 laser optics gray scale difference autocorrelation particle image velocity measurement
  • 相关文献

参考文献10

二级参考文献27

共引文献24

同被引文献10

  • 1Mcpherson R, Gane N, Bastow T. Structural characteriza- tion of plasma sprayed hydroxyapatite coatings [ J ]. Jour- nal of Materials Science-Materials in Medicine, 1995,6 (6) :327-334.
  • 2Yang X Z. Preparation of Bioceramic Films Containing Hydroxyapatites on Ti-6A1-4V Alloy Surfaces by the Mi- cro-arc oxidation Technique [ J ]. Materials Research Bul- letin,2009,44:947-949.
  • 3Chen H T, Hsiao C H. Micro-arc oxidation of I3-titanium Alloy:Structural Characterization and Osteoblast Compati- bility [ J ]. Surface & Coatings Technology, 2009, 204 : 1126-1131.
  • 4Gnedenkov S V, VovnaV I, Gordienko P S, et al. Chemical Composition of Antifrlction Microare Oxidation Coatings on Titanium Alloy BT16 [ J ]. Protection of Metals, 2001, 37(2) :192-196.
  • 5Yerokhin A L,Nie X, Leyland A, et al. Plasma Electroly- sis for Surface Engineering[ J]. Surface & Coatings Tech- nology, 1999,122 ( 2 - 3 ) : 73- 93.
  • 6Wang F B, Di S C, Yu Jie. Biocompatibility research of medicine titanium alloy coating by microarc oxidation [ J ]. Advanced Materials Research,2011,189 (4) :222 ~ 226.
  • 7Sul Y T. The significance of the surface properties of oxi- dized titanium to the bone response: special emphasis on potential biochemical bonding of oxidized titanium implant [ J ]. Biomaterials, 2003,24 ( 22 ) : 3893- 3907.
  • 8Sul Y T ,Johansson C B ,Jeong Y ,et aI. Oxidized implants and their influence on the bone response [ J ]. J Mater SciMater Med ,2001,12 : 1025-1031.
  • 9Li L H, Kong Y M. Improved biological performance of Ti implants due to surface modification by microarc oxidation [ J ]. Biomaterials,2004,25 (14) : 2867- 2875.
  • 10Brunette D M, Tengvall P, Textor M, et al. Titanium in medical [ M ]. Berlin : Springer, 2001 : 127-136.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部