期刊文献+

反相离子对高效液相色谱法测定维生素B_(12)注射液的含量 被引量:2

Determination of Vitamin B_(12) injection by RP-IP-HPLC
下载PDF
导出
摘要 目的:建立维生素B12注射液的含量测定方法。方法:采用Kromasil C18柱,以0.16%庚烷磺酸钠溶液-甲醇(82∶18)(用磷酸调pH值3.0)为流动相,流速为1.0ml/min,检测波长361nm。结果:维生素B12进样量在0.04048~0.6072μg范围内与峰面积呈良好的线性关系,r=0.9999(n=5);平均加样回收率为99.0%(RSD=0.59%,n=6)。结论:该法准确、专属性强、重现性好。 Objective: To establish a method for the determination of Vitamin B12 injection by RP-IP-HPLC.Methods: The determination was performed on a Kromasil C18 column with the mobile phase consisted of 0.16% sodium heptanesul fonate solution-methanol(82∶18)(adjusted to pH 3.0 with phosphoric acid) at ambient temperature.The flow rate was 1.0 ml/min.The detective wavelength was 361 nm.Results: The method showed a good linear relation over the range of 0.040 48-0.607 2 μg (r=0.999 9,n=5).The average recovery was 99.0% for the three different levels of the added amount of Vitamin B12 with RSD=0.59% (n=6).Conclusion: This method is feasible,convenient,specific and reproducible.It can be used to determine the content of Vitamin B12 injection.
出处 《中国当代医药》 2011年第7期44-44,46,共2页 China Modern Medicine
关键词 维生素B12 反相离子对高效液相色谱法 含量测定 Vitamin B12 RP-IP-HPLC Content determination
  • 相关文献

参考文献5

  • 1国家药典委员会.化学药品地方标准上升国家药品标准[S].三册.北京:化学工业出版社,2002:23,27.
  • 2国家药典委员会.化学药品地方标准上升国家药品标准[s].十一册.北京:化学工业出版社,2002:142.
  • 3国家药典委员会.中国药典嗍二部.北京:化学工业出版社,2005:附录28.
  • 4国家药典委员会.中国药典[M].二部(2000年版)2004年增补本.北京:化学工业出版社,2004:128.
  • 5毛舜元,杨观兆,施辛,鲁爱娣.高效液相色谱法测定多种维生素含量[J].药物分析杂志,1995,15(2):25-30. 被引量:25

二级参考文献2

共引文献24

同被引文献6

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部