摘要
本文介绍了科里奥利流量计的计量原理,详细分析了影响流量计准确度的各种因素,给出了影响仪表零点的原因。
This paper introduces coriolis meter theory of operation and describes all factors thatinfluences on meter accuracy,including pressure temperature,external vibration and slugs of gas.Reason that influences on the meter's baseline offset or zero is introduced.
出处
《中国仪器仪表》
1999年第4期38-41,共4页
China Instrumentation