期刊文献+

Sonoclot分析仪在体外循环冠脉旁路移植术中的应用评价 被引量:2

Estimation of Sonoclot Analyzer in Extracorporeal Circulation Coronary Artery Bypass Grafting
下载PDF
导出
摘要 目的:用Sonoclot血小板功能分析仪监测体外循环(ECC)冠状动脉旁路移植术(CABG)中凝血功能的变化。方法:随机选择20例ECC下行CABG病人,在全麻诱导前(T1)、停机并用鱼精蛋白中和后10 min(T2)及手术结束(T3)时抽取血样,检测血小板功能和ACT、PT、APTT、Fib、TT、Hb。结果:与T1比较,T2和T3的PT、APTT、TT延长,Fib下降,ACT延长,CR、PF下降,T3与T2比较凝血时间缩短。结论:Sonoclot分析仪能够较为准确地监测ECC后凝血功能的变化。 Objective: To monitor the changes in blood coagulation with sonoclot platelet functional analyzer during extracorporeal circulation(ECC) coronary artery bypass grafting(CABG).Methods: Twenty cases with CABG were randomly selected.Blood was taken to test platelet function,ACT,PT,APTT,Fib,TT,and Hb before induction of general anesthesia(T1),at 10 min after protamin neutralization(T2),and at the end of surgery(T3).Results: Compared with those at T1,the value at T2 and T3 of PT,APTT,TT and ACT increased,CR,PF and Fib decreased.Moreover,compared with T2,coagulation time decreased at T3.Conclusion: Sonoclot analyzer can monitor the changes in coagulation function after ECC.
出处 《包头医学院学报》 CAS 2011年第1期46-48,共3页 Journal of Baotou Medical College
关键词 血小板功能分析仪 凝血功能 体外循环 Platelet functional analyzer Coagulation function Extracorporeal circulation
  • 相关文献

参考文献8

  • 1王仕刚,龙村,高国栋.用Sonoclot分析仪测评体外循环后凝血功能的改变[J].中国体外循环杂志,2008,6(4):220-222. 被引量:6
  • 2Paparella D, Brister SJ, Buchanan MR. Coagulation disorders of cardiopulmonary bypass: a review [ J ]. Inrensive Care Med,2004,30(10) : 1873 - 1881.
  • 3Rand ML, Leung R, Packhum MA. Platelet function assays [ J]. Transfus Apheresis SCI,2003,28:307 - 317.
  • 4Harrison P. Platelet function analysis [ J ]. Blood REV,2005, 19:111 -123.
  • 5武宙阳.Sonoclot凝血与血小板功能分析仪在体外循环中的应用[J].国外医学(麻醉学与复苏分册),2003,24(1):55-57. 被引量:9
  • 6Tetsuya M, Masakazu K. Evaluation of platelet function by Sonoclot analysis compared with other hemostatic variables in cardiac surgery [ J ]. Anesth Analg, 1998,87 ( 6 ) : 1228 - 1233.
  • 7Ferraris VA, Ferraris SP, Saha SP, et al. Perioperative blood transfusion and blood conservation in cardiac surgery:the society of thoracic surgeons and the society of cardiovascular anesthesiologists clinical practice guideline [ J ]. Ann Thorac Surg,2007,83 : s27 - s86.
  • 8Kamada Y, Yamakage M, Niiya T, et al. Celite -activated viscometer Sonoclot can measure the suppressive effect of tranexamic acid on hyperfibrinolysis in cardiac surgery[ J ]. J Anesth ,2001,15 ( 1 ) : 17 - 21.

二级参考文献25

  • 1[2]Miyashita T,Kuro M.Evaluation of Platelet Functian by Sonoclot Analysis Compared with Other Hemostatic Variables in Cardiac Surgery[J].Anesth Analg,1998,87(6):1228-1233.
  • 2[3]Faraday N,Guallar E,Sera VA,et al.Utility of whole blood hemostatometry using the clot signature analyzer for assessment of hemostasis in cardiac surgery[J].Anesthesiology,2002,96(5):1115-1122.
  • 3[4]Hett DA,Walker D,Pilkington SN,et al.Sonoclot analysis[J].Br J Anaesth,1995,75(6):771-776.
  • 4[5]Kamada Y,Yamakage M,Niiya T,et al.Celite-activated viscometer Sonoclot can measure the suppressive effect of tranexamic acid on hyperfibrinolysis in cardiac surgery[J].J Anesth,2001,15(1):17-21.
  • 5[6]Yamada T,Katori N,Tanaka KA,et al.Impact of Sonoclot hemostasis analysis after cardiopulmonary bypass on postoperative hemorrhage in cardiac surgery[J].J Anesth,2007,21(2):148-152.
  • 6[7]Dalbert S,Canter MT,Furrer L,et al.Effects of heparin,haemodilution and aprotinin on kaolin-based activated clotting time:in vitro comparison of two different points of care devices[J].Acta Anaesthesiol Scand,2006,50(4):461-468.
  • 7[8]Ganter MT,Monn A,Tavakoli R,et al.Monitoring activated clotting time for combined heparin and aprotinin application:in vivo evaluation of a new aprotinin-insensitive test using Sonoclot[J].Eur J Cardiothorac Surg,2006,30(2):278-284.
  • 8Shenaq SA, Saleem A. Viscoelastic measurement of clot formation: the sonoclot. In: Ellison N, Jobes DR, eds. Effective Hemostasis in Cardiac Surgery. Philadelphia:W. B. Saunders, 1988,183-193.
  • 9Hett DA, Walker D, Pilkington SN, et al. Sonoclot analysis. Br J Anaesth 1995,75(6) :771-776.
  • 10Kjellberg U, Hellgren M. Sonoclot signature during normal pregnancy. Intensive Care Med, 2000,26(2): 206-211.

共引文献13

同被引文献24

  • 1吴志云,蔡骅,王永盛,陈建洪.Sonoclot凝血分析用于DIC的治疗[J].临床军医杂志,2005,33(3):366-367. 被引量:2
  • 2MICHAEL A, MICHAEl. T, CHRISTINE R, et al. Platelet function monitoring with the Sonoclot analy- zer after in vitro tiro.9 ban and heparin administration [J]. J Thorae Cardiovasc Surg, 2006, 131: 1314- 1322.
  • 3JONATHAN H, WATERS, DAVID G, et al. Bleeding in a patient receiving platelet aggregation inhibitors [J]. Anesth Analg, 2001,93 : 878- 882.
  • 4CAROLINE U, NILSSON, MARTIN ENGSTROM. Monitoring fondaparinux with the Sonoclot [J]. Blood Coagu[ Fibrinolysis,2007,18 : 619- 622.
  • 5MICHAEl. T, ANTOINETTE MONN, REZA TAV AKOLI,et aL Kaolin-based activated coagulation time measured by sonoclot in patients undergoing cardiop- ulmonary bypass [J ]. Journal of Cardiothoracic and Vascular Anesthesia, 2007,21 : 524- 528.
  • 6DONG Y, NUTTALL G A, OLIVER W C, et al. Aprotinin does not prolong the Sonoclot aprotinin-in- sensitive activated clotting time[J]. Journal of Clinical Anesthesia, 2007,19 ..424-428.
  • 7HILDE PLEYM, ALEXANDER WAHBA, LISE BJ- ELLA,et al. Sonoclot analysis in coronary artery sur- gery: a comparison between patients with unstable coronary artery disease treated with enoxaparin before surgery and patients with stable coronary artery dis ease not treated with enoxaparin[J]. Journal of Car- diothoracic and Vascular Anesthesia, 2008,22 .. 670 - 674.
  • 8FERRARIS V A,FERRARIS S P,SAHA S P,et al. Pcrioperative blood transfusion and blood conservation in cardiac surgery: the ciety of thoracic surgeons and the society of cardiovascular anesthesiologists clinical practice guideline[. Ann Thorac Surg, 2007,83 : s27 -s86.
  • 9CASUTT M, KRISTOFFY A, SCHUEPFER G, et al. Effects on coagulation of balanced (130/0. 42) and non-balanced (130/0.4) hydroxyethyl starch or gelat- in compared with balanced Ringer's solution., an in vitro study using two different viscoelastic coagulation tests ROTEMTM and SONOCLOTTM [. British Journal of Anaesthesia, 2010,105 : 273 - 281.
  • 10VIKRAM AGGARWAL, POONAM MALHOTRA KAPOOR,MINATI CHOUDHURY, et al. Utility of Sonoclot analysis and tranexamic acid in tetralogy of Fallot patients undergoing intraeardiac repair[. An- nals of Cardiac Anaesthesia, 2012,15 .. 26- 31.