期刊文献+

超低频振动国家计量基准装置的研究与建立 被引量:7

Study and Establishment of the National Standard of the Ultra-low frequency Vibration
下载PDF
导出
摘要 根据超低频振动标准装置的研究现状和应用需求,研究和建立了国家振动幅值和相位基准装置,其频率为0.002Hz~160Hz、振幅为峰峰1m、承载30k、加速度波形失真度〈1%。介绍了装置的结构组成,描述了大行程水平振动台的设计方案、反馈控制技术、管线拖曳系统和激光测振系统,给出了装置的主要技术指标和比对实验数据。解决了我国超低频振动计量的溯源问题。 According to the research status and application requirements for ultra-low frequency vibration standard at home and abroad, the national standard device for vibration magnitude and phasewas studied and established. The ultra-low frequency range is 0. 002 Hz to 160 Hz. The maximum peak-to-peak value of amplitude is lm. The maximum load is 30 kg. The distortion of acceleration waveform is less than 1%. The structure composition of the device and the key technologies solved are introduced. The design project of the long-stroke horizontal vibrator, the negative-feedback control technology, the pipeline dragging synchronous tracking control system and the laser vibration measuring system are described. The main technical specifications of the standard device and the results of comparison experiment are given. The establishment of the national standard device can solve the quantity traceability problem of the ultra-low frequency vibration metrology.
出处 《计量学报》 CSCD 北大核心 2011年第2期97-100,共4页 Acta Metrologica Sinica
基金 国家科技基础条件平台专项(APT(0611-0811)-3) 教育部新世纪优秀人才计划(NCET-0S-0494) 浙江省钱江人才计划(2009R10026)
关键词 计量学 超低频振动基准 零差正弦逼近法 负反馈控制 激光干涉仪 同步跟踪控制 Metrology Uhra-low frequency vibration national standard Homodyne sine-approximation method Negative-feedback control system Laser interferometer Synchronous tracking control
  • 相关文献

参考文献9

二级参考文献20

  • 1孙桥,于梅.振动测量中正弦逼近法的软件实现及研究[J].中国计量,2004(10):73-74. 被引量:7
  • 2于梅,孙桥,冯源,马明德.正弦逼近法振动传感器幅相特性测量技术的研究[J].计量学报,2004,25(4):344-348. 被引量:26
  • 3于梅,孙桥.外差式激光干涉仪应用于正弦直线和旋转振动测量技术的研究[J].计量学报,2005,26(3):237-241. 被引量:17
  • 4[2]ISO 16063-11.Methods for the calibration of vibration and shock transducers-Part Ⅱ:Primary vibration calibration by laser interferometry(1999)[S].
  • 5Richard C Doff,Robert H Bishop.现代控制系统(第8版)[M].谢红位,等译.北京:高等教育出版社,2004,196-232.
  • 6Texas Instruments Incorporated. TEXAS INSTRUMENTS, TMS320F281x Data Sheet[Z]. US, 2004.
  • 7Liu Y H, Huang Y J. The Design and Implementation of Proportional Feedback Controller for the Distortion Improvement of Vibrator in Low Frequency Motion [ J ]. Journal of low frequency noise, vibration and control, 2003,22(3) : 173 - 181.
  • 8Lu Z B, He W, Jia S S. Development of Vibration Environment for Calibration Ultra - low - frequency Seismometers [ C ]//International Symposium on Precision Mechanical Measurement, Hefei, China: 2002.
  • 9Sill R D. A quadrature laser interferometer for accelerometer calibraion[D]. Endevco, TP 316, 2000.
  • 10ISO 16063 - 11. Methods for the calibration of vibration and shock transducers - Part 11: Primary vibration calibration by laser interferometry (third edition) [ S].

共引文献38

同被引文献39

引证文献7

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部