期刊文献+

基于光纤光栅传感技术的变压器温度检测系统 被引量:2

Measuring Technology of Transformer Internal Temperature Based on FBG Sensors
原文传递
导出
摘要 结合目前光纤温度传感器的研究现状,以及变压器内部温度测量的具体要求,设计了一种光纤光栅温度测量的具体方案,选择了合适的硬件,搭建了基于乌溪江电厂油浸式温升用试验变压器的光纤光栅温度测量平台。应用光纤光栅温度传感器对变压器在恒定负载以及变化负载情况下的绕组发热情况进行了测量。实验证明,光纤光栅温度传感器的测量结果准确稳定,对温度的变化反应迅速,能够有效地对变压器内部温度进行测量。 Based on current status of existing fiber-optic temperature sensor and specific requirements of internal temperature measurement(TM) of transformers,a concrete scheme of FBG temperature sensor is designed.Besides,a FBG TM platform is designed with selecting appropriate hardware and specific programs for TM platform.The latter is suitable for TM of oil-immersed transformer of Wuxijiang Power Plant.Winding TM test of the transformer was completed with FBG temperature sensor under constant load and varying load.The test results show that FBG temperature sensor is an effective instrument for measuring internal temperature of transformers with high accuracy and fast response to temperature change.
出处 《水电自动化与大坝监测》 2011年第1期32-35,50,共5页 HYDROPOWER AUTOMATION AND DAM MONITORING
关键词 变压器 温度检测系统 光纤光栅 power transformer temperature measurement system fiber Bragg grating(FBG)
  • 相关文献

参考文献4

二级参考文献4

  • 1DL/T5211-2005大坝安全监测自动化技术规范.北京:中国电力出版社,2005.
  • 2MAYO J.C#技术内幕.王启丁,高锦文,刘明,等译.北京:机械工业出版社,2003.
  • 3LARMAN C.UML和模式应用.方梁,等译.北京:北京理工大学出版社,2004.
  • 4赵斌,赵志勇,邱小弟,廖占勇,崔岗.小湾水电站安全监测自动化系统的总体设计[J].水电自动化与大坝监测,2008,32(6):53-57. 被引量:10

共引文献20

同被引文献14

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部