期刊文献+

一种非接触式钢管中频加热温度的测量方法

One kind of un- touching method in testing steel pipe's mid- frequency heat temperature
下载PDF
导出
摘要 目前国内管道防腐加工厂在生产中,通常采用直接接触式测量方法,即用测温笔测量中频加热后钢管表面的温度,而忽略非接触式测量方法,或误认非接触式测量方法不准确。针对这一现状,介绍了一种非接触式钢管中频加热温度的测量方法,与直接接触式测量方法进行了对比,讨论了影响非接触式钢管中频加热温度的测量方法准确性的因素,应用结果表明非接触式钢管中频加热温度的测量方法具有更高的准确性,与接触式测温配合使用、互为补充增强了测温的可靠性。 Generally direct- touching and un -touching are two methods in testing the steel pipess temperature during the coating production, the two methods have their advantages and disadvantages respectively, we could not rely on or exclude one of the two methods too much, we might make up of the two methods to get the true and precise temperature. One kind of un -touching method have been introduced, and compared with the direct - touching method, the impact factors in testing temperature have been discussed too, the application results showed that this kind of un - touching method can give us much more true and precise temperature of the steel pipe.
出处 《防腐保温技术》 2011年第1期22-24,共3页 Anticorrosion & Insulation Technology
关键词 管道防腐 温度控制 温度测量 测温笔 红外测温 pipeline coating, temperature control, temperature testing, tempilstick, infrared testing temperature
  • 相关文献

参考文献3

二级参考文献15

  • 1徐金卿.红外物理与技术[M].西安:西安电子科技大学出版社,1989.310-314.
  • 2周书栓.红外辐射测量基础[M].上海:上海交通大学出版社,1991..
  • 3服部晋 位田敏和 等.简易辐射温度计[J].日本赤外线学会志,1996,6(2):21-27.
  • 4安藤哲男 大沼修.新式双色温度计[J].红外,1988,(10):36-38.
  • 5王伯雄 马秉林.微机控制的红外测温技术[J].微电子学与计算机,1986,3(4):26-28.
  • 6崔志尚,温度计量与测试,1998年,140页
  • 7徐南荣,红外辐射与制导,1997年,9页
  • 8陈玻若,红外系统,1995年,146页
  • 9周书栓,红外辐射测量基础,1991年
  • 10刘梅冬,压电铁电材料与器件,1990年,234页

共引文献67