期刊文献+

基于声纳技术的截流深井淤积研究 被引量:4

Research on Siltation Condition of Deep Intercepting Wells Based on Sonar
原文传递
导出
摘要 在排水设施检测中,声纳探测是一种方便高效的检测方法。在柳州市河北环岛截污工程的壅水式截流深井的淤积状况检测中采用了声纳检测系统,探测结果显示:壅水式截流深井内已形成较严重的淤积,淤泥厚度为1.1~1.9m;截流深井的淤泥面呈现出相似的形状,纵向淤泥面呈斜坡状,坡度一般在30°左右,横向淤泥面呈凹面锅底状。经分析,壅水式截流深井淤积的原因主要是由于溢流堰的阻挡,使水流方向由水平变为上升;此外,截流井室过水断面面积较大导致的水流速度长期小于不淤流速,也是截流深井发生淤积的重要原因。 Sonar system is a convenient and efficient tool to inspect drainage facilities. Sonar system was used to inspect the siltation condition of deep intercepting well with damming in the sewage inter- ception project around island of north river in Liuzhou City. The inspection results prove that there is serious deposition with silt depth between 1.1 m and 1.9 m in the deep intercepting well with damming. The silt surface shape in deep intercepting wells is similar, that is, the longitudinal silt surface is a slope with about 30 degree gradient, and the transverse silt surface is a concave surface as hollowware bottom. After analysis, the reason of siltation in deep intercepting well with damming is that the flow changes from hori- zontal direction to vertical direction because of the obstacle of overflow weir. Furthermore, it is another major cause contributing to siltation that the flow section in intercepting room is larger and then the flow velocity is less than non-sihing velocity in long term.
出处 《中国给水排水》 CAS CSCD 北大核心 2011年第5期6-8,共3页 China Water & Wastewater
基金 国家水体污染控制与治理科技重大专项(2008ZX07317-001)
关键词 壅水式截流深井 淤积 声纳 探测 deep intercepting well with damming siltation: sonar, inspection
  • 相关文献

参考文献5

  • 1李田,郑瑞东,朱军.排水管道检测技术的发展现状[J].中国给水排水,2006,22(12):11-13. 被引量:62
  • 2Gomez F, Ahhoefer K, Seneviratne L D. An ultrasonic profiling method for sewer inspection[ A]. 2004 IEEE International Conference on Robotics and Automation [ C ]. New Orleans: IEEE Robotics and Automation Society, 2004.
  • 3Duran O,Ahhoefer K, Seneviratne L. State of the art in sensor technologies for sewer inspection [ J ] Sensors J, 2002,2(2) :73 - 81.
  • 4庞德刚.浅议柳州市排水规划[J].广西大学学报(自然科学版),2002,27(z1):32-35. 被引量:2
  • 5Gomez F, Althoefer K, Seneviratne L D. Simulation of ultrasound imaging inside fully charged pipes[J]. Automation in Construction ,2006,15 ( 3 ) :355 - 364.

二级参考文献7

  • 1陈斌.城市排涝与排水研究[J].给水排水,1996,22(9):17-20. 被引量:21
  • 2Sinha Sunil K.State-of-the-art in sensor technologies for pipe inspection[A].Proceedings of the ASCE International Conference on Pipeline Engineering and Construction:New Pipeline Technologies,Security and Safety[C].Washington D C:ASCE,2003.
  • 3Reini Wirahadikusumah,Dulcy M Abraham,Tom Iseley,et al.Assessment technologies for sewer system rehabilitation[J].Autom in Construction,1998,7 (4):259 -270.
  • 4Sanjiv Gokhale,Jeffrey A Graham.A new development in locating leaks in sanitary sewers[J].Tunnelling and Underground Space Technology,2004,19 (2):85-96.
  • 5Eiswirth M,Frey C,Herbst J,et al.Sewer Assessment by Multi-sensor Systems[M].Berlin:IWA2 World Water Congress,2001.
  • 6Sinha Sunil K,Fieguth Paul W.Segmentation of buried concrete pipe images[J].Autom in Construction,2006,15(1):47 -57.
  • 7周斌.华东地区城市污水处理厂运行成本分析[J].中国给水排水,2001,17(8):29-30. 被引量:37

共引文献62

同被引文献26

引证文献4

二级引证文献8