专栏——乳腺摄影(诊断物理)质量控制 被引量:4

Analysis of Mammography Dose and Low Contrast Film Quality
下载PDF
导出
摘要 乳腺X射线检查是目前国际公认的有效检测乳腺癌的方法,对图像质量和系统稳定性要求非常高,不当的乳腺检测不但达不到准确检出疾病的目的,还可能因为X射线的过量使用而诱发乳腺疾病的发生,因此相关设备和摄影过程的质量控制尤为重要。本期专栏分别探讨了乳腺摄影剂量与低对比模体影像质量的关系,以及乳腺数字图像的软阅读与平均像素分析,希望能为促进行业内乳腺摄影质量控制发展提供借鉴。 Objective To analyse the relationship of the dose parameters of mammary gland automatic radiography model settings and low contrast image quality and the mammary gland dose of average in physical form measurement.Methods First,used three kinds of automatic radiography model(CNT contrast mode,STD standard mode,dose mode),illuminate 18-220 and 18-222 phantoms respectively,then illuminates a contrast-detail mammography(CDMAM) phantom which added three or four Acrylic boards(1cm) respectively.According to CDMAM test requirements,selected the upper and lower doses settings,CDMAM for exposure,obtained image analysis data.Results The CDMAM analysis data with three acrylic boards and 18-220 phantom dose is basically the same parameters,For CDMAM using three acrylic board,The AGD of CNT mode is twice the STD mode,IQFinv increased five to seven;The AGD of STD mode relatively Dose mode increased by 15%,IQFinv increased 8% to 13%.Conclusion First,the radiation dose excessive rise will not bring the corresponding low contrast performance effect;second,CNT mode and Dose mode is not suitable for routine examination,only the particular circumstances may use.Third,On the premise of image quality guarantee,The reference data and clinical other inspection of photography model is one of the effective solutions.to reduce the client radiation dose.
出处 《中国医疗设备》 2011年第3期1-3,共3页 China Medical Devices
关键词 乳腺摄影机 乳腺自动摄影模式 平均腺体剂量(AGD) 乳腺低对比性能模体(CDMAM) 影像品质系数(IQFinv) mammography system mammary gland automatic radiography model average glands dose(AGD) contrast-detail mammography(CDMAM) phantom image quality figure(IQFinv)
  • 相关文献

参考文献2

二级参考文献7

共引文献26

同被引文献35

  • 1Van Ongeval C, Bosmans H, Van Steen A, et al. Evaluation of the diagnostic value of a computed radiography system by comparison of digital hard copy images with screen-film mammography: results of a prospective clinical trial[J]. Eur Radiol,2006,16:1360-1366.
  • 2Saunders RS, Samei E, Jesneck JL, et al. Physical characterization of a prototype selenium-based full field digital mammography detector [J].Med Phys,2005,32:588-599.
  • 3Doyle P, Martin CJ, Gentle D. Application of contrast-to-noise ration in optimizing beam quality for digital chest radiography: comparison of experimental measurements and theoretical simulations[J]. Phys Med Biol,2006, 51:2953-2970.
  • 4Gingold EL, Xizeng W, Barnes GT. Contrast and dose with Mo-Mo, Mo-Rh and Rh-Rh target-filter combinations in mammography[J]. Radiology,1995,195:639-644.
  • 5Dance DR, Thilander Klang A, Sandborg M, et al. Influence of anode/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: a Monte Carlo study[J]. BrJ Radiol,2000,73:1056-1067.
  • 6Fahfig R,Rowlands JA,Yaffe MJ.X-ray imaging with amorphous selenium:Optimal spectra for digital mammography[J].Med Phys,1996,23:557-567.
  • 7Young KC. Breast dose surveys in the NHSBSP: software and instruction manual,Version 2.0[M].NHSBSP Report 04/05, Guild ford,2004.
  • 8Dance DR, Skinner CL, Young KC, et al. Additional factors for estimation of mean glandular breast dose using the UK mammography dosimetry protocol[J]. Phys Med Biol,2000, 45:3225-3240.
  • 9Perry N,Broeders M,de Wolf C,et al.European guidelines for quality assurance in breast cancer screening and diagnosis,4th edition[M]. European Communities,2006,Luxembourg: chapter 2.
  • 10Toroi P,Zanca F,Young KC,et al.Experimental investigation on the choice of the tungsten/rhodium anode/filter combination for an amorphous selenium-based digital mammography system[J]. Eur Radiol,2007,17:236B-2375.

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部