一种从冠状动脉X线造影生成最佳投照角度的新方法
被引量:2
摘要
虽然冠状动脉介入治疗是治疗冠心病最主要的方法之一,但其一定比例的再狭窄率以及由再狭窄和支架内血栓所导致的高病死率和高致残率仍限制着该方法的进一步应用。
出处
《中华放射学杂志》
CAS
CSCD
北大核心
2011年第2期195-198,共4页
Chinese Journal of Radiology
参考文献10
-
1Costa MA,Angiolillo DJ,Tannenbaum M,et al.Impact of stent deployment procedural factors on long-term effectiveness and safety of sirolimus-eluting stents (final results of the multicenter prospective STLLR trial).Am J Cardiol,2008,101:1704-1711.
-
2Dumay AM,Reiber JC,Gerbrands JJ.Determination of optimal angiographic viewing angles:basic principles and evaluation study.IEEE Trans Med Imaging,1994,13:13-24.
-
3Sadamatsu K,Sagara S,Yamawaki T,et al.Three-dimensional coronary imaging for the ostium of the left anterior descending artery.Int J Cardiovasc Imaging,2009,25:223-228.
-
4Tu S,Koning G,Jukema W,et al.Assessment of obstruction length and optimal viewing angle from biplane X-ray angiograms.Int J Cardiovasc Imaging,2010,26:5-17.
-
5Green NE,Chen SY,Hansgen AR,et al.Angiographic views used for percutaneous coronary interventions:a three-dimensional analysis of physician-determined vs.computer-generated views.Catheter Cardiovasc Interv,2005,64:451-459.
-
6Reiber JH,Serruys PW,Kooijman CJ,et al.Assessment of short,medium,and long term variations in arterial dimensions from computer assisted quantitation of coronary cineangiograms.Circulation,1985,71:280-288.
-
7Tu S,Koning G,Tuinenburg JC,et al.Coronary angiography enhancement for visualization.Int J Cardiovasc Imaging,2009,25:657-667.
-
8Agostoni P,Biondi-Zoccai G,Van Langenhove G,et al.Comparison of assessment of native coronary arteries by standard versus three-dimensional coronary angiography.Am J Cardiol,2008,102:272-279.
-
9Rittger H,Schertel B,Schmidt M,et al.Three-dimensional reconstruction allows accurate quantification and length measurements of coronary artery stenoses.Eurolntervention,2009,5:127-132.
-
10Tu S,Huang Z,Koning G,et al.A novel three-dimensional quantitative coronary angiography system:In-vivo comparison with intravascular ultrasound for assessing arterial segment length.Catheter Cardiovasc Interv,2010,76:291-298.
同被引文献29
-
1李信友,曾勇明,陆云峰,谭欢.平板探测器DSA冠状动脉造影的临床应用及评价[J].实用医学影像杂志,2005,6(6):304-306. 被引量:4
-
2苗英,钱玉娥,张月俏.16层螺旋CT低剂量扫描在女性骨盆中的应用[J].中华放射医学与防护杂志,2006,26(1):90-91. 被引量:29
-
3王金龙,凌锋,李慎茂,朱凤水,宋庆斌.实用投照角度在缺血性脑血管病介入检查及治疗中的应用[J].介入放射学杂志,2007,16(5):344-348. 被引量:5
-
4白玫,刘彬,郑钧正.心脏介入患者受照剂量研究[J].介入放射学杂志,2007,16(4):222-225. 被引量:14
-
5Douglas P, Zi P, Peter L, et al. Braunwald's heart diease: a text-book of cardiovseular medicine[M]. 7th edition,北京:人民卫生出版社,2007:410-411.
-
6Kocinaj D, Cioppa A, Ambrosini G, et al. Radiation dose expo- sure during cardiac and peripheral arteries catheterisation[J], lnt J Cardiol,2006,113(2) :283-284.
-
7Briguori C, Airoldi F, Dandrea D, et al. Renal insufficiency fol- lowing contrast media administration trial (REMEDIAL) : a ran- domized comparison of 3 preventive strategies[J]. Circulation, 2007,115 (10) : 1211-1217.
-
8Tu S, Koning G, Jukema W, et al. Assessment of obstruction length and optimal viewing angle from biplane X-ray angiograms [J]. Int J Cardiovasc Imaging, 2010,26 (1) : 5-17.
-
9Tu S, Huang Z, Koning G, et al. A novel three-dimensional quantitative coronary angiagraphy system: imvivo comparison with intravascular ultrasound for assessing arterial segment length [J]. Catheter Cardiovase Interv,2010,76(2) :291-298.
-
10马长生.冠心病介人治疗-技术与策略[M].2版,北京:人民卫生出版社,2007:3-4.
引证文献2
-
1邵会雨,梁明,王效增,姚天明,孙景阳,梁延春,王猛,韩雅玲.野战方舱内冠状动脉造影投照体位对辐射剂量和影像质量的影响[J].介入放射学杂志,2012,21(10):843-846. 被引量:4
-
2郝培远,高传玉,陈爱华,宋旭东,李志樑,袁义强.冠状动脉三维重建各血管段最佳投照角度的分布规律[J].中华高血压杂志,2013,21(10):959-964. 被引量:3
二级引证文献7
-
1孙建平,卢微,张英.方舱内微创介入诊治急性心肌梗死的临床研究[J].当代医学,2014,20(36):84-85.
-
2赵石有.探究不同体位对肠镜检查结果的影响[J].中外医疗,2014,33(26):185-186. 被引量:2
-
3宣风琦,梁明,孙景阳,荣晶晶,赵丽军,姚天明,王效增,李菲,韩雅玲.微创介入手术方舱开展冠心病介入诊疗对患者肾功能影响[J].创伤与急危重病医学,2015,3(2):84-86. 被引量:3
-
4张祥海,周林,李君,闫红野,张靖.右冠状动脉左45°造影测量准确性研究[J].实用放射学杂志,2019,35(6):967-969. 被引量:1
-
5金德昊,陈超,张建,刘勇成,李春苗,孙明虎,刘月.冠状动脉介入诊疗过程中术者辐射剂量分析[J].中国临床医学影像杂志,2020,31(11):809-812. 被引量:2
-
6张祥海,闫红野,周林,刘倩,廖春,张乐天.冠状动脉前降支不同造影体位和图像区域测量准确性分析[J].医学影像学杂志,2023,33(3):417-421. 被引量:2
-
7柳杨,田峰,荆晶,陈韵岱.三维定量冠脉造影在冠心病介入治疗中的作用综述[J].解放军医学院学报,2019,40(7):695-698. 被引量:5
-
1卞玉刚,张纪,郭炜,王耀程.颈椎斜位最佳投照角度的模拟测试[J].实用放射学杂志,2000,16(12):753-754. 被引量:3
-
2张奇,陈伟,张泽坤,李智勇,王博,刘松,张英泽.股骨颈骨折X线最佳投照角度的实验研究[J].河北医科大学学报,2010,31(9):1115-1117. 被引量:8
-
3周珊珊,郝培远,陈爱华,宋旭东,魏向龙,何非,涂圣贤.右冠分叉病变三维重建最佳投照角度与介入投照角度的对照研究[J].实用医学杂志,2011,27(16):2943-2946. 被引量:1
-
4潘进社,张英泽,侯志勇,郑占乐,李艳宝,杨毅鹏.髋臼前柱轴位像的投照方法与应用[J].河北医科大学学报,2009,30(10). 被引量:1
-
5陈爱华,郝培远,周珊珊,宋旭东,魏向龙,何非,李志樑.冠脉造影单支病变靶血管最佳投照角度与介入角度的分析对照研究[J].中华高血压杂志,2011,19(2):153-158. 被引量:5
-
6潘进社,李艳宝,郑占乐.髋臼后柱轴位像在经皮固定后柱中的应用[J].河北医科大学学报,2009,30(10):1077-1078.
-
7锡林宝勒日,陈刚,白靖平,刘应祯,陈慰民,武忠炎,冯成堂.脊髓造影斜位片诊断腰椎间盘突出症价值的探讨[J].现代医用影像学,2003,12(5):198-203.
-
8梁文华,钱立.肘关节斜位投照方法选择及临床应用价值初探[J].影像诊断与介入放射学,2004,13(1):53-55. 被引量:6