期刊文献+

高强度聚焦超声(HIFU)肿瘤热消融技术的关键问题简析 被引量:8

Analysis of key problem of high intensity focused ultrasound (HIFU) thermal ablation technique
原文传递
导出
摘要 目的 1988年,王智彪萌发了用高强度聚焦超声(highintensity focused ultrasound,HIFU)从体外对体内肿瘤进行非侵入切除的灵感。在之后的10年中,他和他的团队在该领域提出了“生物学焦域”、“超声治疗剂量学”、“组织声环境”等概念。在实时超声监控、治疗系统优化、远程医疗系统、临床方案等方面突破了相应的关键技术壁垒。将HIFU治疗技术成功运用于外科治疗,在国际上积累了数量最多的临床病例。在该领域的设备研制、临床应用及若干基础研究方面走在了世界前列。 In 1988, Zhibiao Wang had an inspiration of ablating tumor in vivo non-invasively by high intensity fo- cused ultrasound (HIFU). In the following 10 years, he and his team first proposed concepts such as "biological focal region", " ultrasound therapy dosimetry", " acoustic environment in tissue" and so on. They had broken down the key technical barriers in real-time ultrasound monitoring, treatment system optimization, telemedicine system, clinical protocols and other aspects, making HIFU therapy successfully applied to surgery and accumulated the largest number of clinical cases internationally. They have been playing a leading role around the world in equipment development, clinical application and some basic research in this field.
作者 李发琪
出处 《中华肝胆外科杂志》 CAS CSCD 北大核心 2011年第2期175-176,共2页 Chinese Journal of Hepatobiliary Surgery
关键词 高强度聚焦超声 消融治疗 肿瘤 关键技术 High intensity focused ultrasound Ablated therapy Tumour Key technology
  • 相关文献

参考文献12

  • 1Lacefield JC,Pilkington WC,Waag RC.Distributed aberrators for emulation of ultrasonic pulse distortion by abdominal wall.ARLO,2002,3:47-51.
  • 2Divkovic GW,Liebler M,Braun K,et al.Thermal properties and changes of acoustic parameters in an egg white phantom during heating and coagulation by high intensity focused ultrasound.Ultrasound Med Biol,2007,33:981-986.
  • 3Zderic V,Keshavarzi A,Andrew MA,et al.Attenuation of porcine tissues in vivo after high-intensity ultrasound treatment.Ultrasound Med Biol,2004,30:61-66.
  • 4Rabkin BA.Biological and physical mechanisms of HIFU-induced hyperecho in ultrasound images.Ultrasound Med Biol,2006,32:1721-1729.
  • 5Khokhlova VA,Bailey M,Reed JA,et al.Effects of nonlinear propagation,cavitation,and boiling in lesion formation by high intensity focused ultrasound in a gel phantom.J Acoust Soc,2005,119:1834-1848.
  • 6Wang ZB,Wu F,Wang ZL,et al.Targeted damage effects of high intensity focused ultrasound (HIFU) on liver tissues of Guizhou province miniswin.Ultrason Sonochem,1997,4:181-182.
  • 7Mason TJ.Report on first international workshop on the application of high intensity focused ultrasound in medicine.Chongqing,P.R.China (10-13 May 2001).Ultrason Sonochem,2002,9:121-122.
  • 8Wang ZB,Bai J,Li FQ,et al.Study of a "biological focal region"of high intensity focused ultrasoun.Ultrasound Med Biol.2003,29:749-754.
  • 9Wang ZB,Li FQ,Bai J,et al.Study on energy efficiency factor of ultrasound therapy.2nd international symposium on therapeutic ultrasound.29 July-2 August 2002,Seattle,Washington USA,Conference Proceeding.P49-56.
  • 10Wang ZB,Li FQ,Bai J,et al.A study of acoustic environment in tissue of high intensity focused ultrasound.3rd international symposium on therapeutic ultrasound.22-25 June 2003,Lyon,France,P68.

同被引文献98

引证文献8

二级引证文献61

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部