期刊文献+

Condition Assessment of Oil-Paper Transformer Insulating System

Condition Assessment of Oil-Paper Transformer Insulating System
下载PDF
导出
摘要 Damages of power transformers are caused partly by construction setting but also by operation (i. e., due to operational and degradation parameters). A long-term operation and exceeding of the limit values of transformer abbreviate the lifetime of this device very dramatically. A condition of insulating system oilpaper is principal diagnostic indicator that has its essential influence to failure-free operation of power transformers. The paper deals with a description of the experience with developed monitoring system, which is focused mainly on a control of oil filling of experimental transformer. Relative humidity, amount of dissolved gases and increased temperature are observed, as they have decisive influence on insulating system of transformer. Monitoring of these characteristics is completed with analysis of oil samples by infrared spectroscopy in mode of Attenuated Total Reflection technique.
出处 《Journal of Energy and Power Engineering》 2011年第2期173-178,共6页 能源与动力工程(美国大卫英文)
关键词 Monitoring system TRANSFORMER infrared spectroscopy gas chromatography 电力变压器 绝缘系统 状态评估 油纸 红外光谱技术 监测系统 无故障运行 衰减全反射
  • 相关文献

参考文献11

  • 1T. K. Saha, Review of modem diagnostic techniques for assessing insulation condition in aged transformers, IEEE Transactions on Dielectrics and Electrical Insulation 10 (2003) 903-917.
  • 2K. Najdenkoski, G. Rafajlovski, V. Dimcev, Thermal aging of distribution transformers, Power Engineering Society General Meeting, Tampa, FL, 2007.
  • 3R. Walling, G.B. Shattuck, Distribution transformer thermal behavior and aging in local-delivery distribution systems, 19th International Conference on Electricity Distribution, Vienna, 2007, Paper No. 0720.
  • 4V. Mentlik, P. Prosr, R. Polansky, J. Michalik, M. Brandt, Inslnunents for on-line monitoring of transformers, International Conference on Renewable Energies and Power Quality, Spain, 2009.
  • 5V.M. Montsinger, Loading transformer by temperature, AIEE transactions 49 (1930) 776-792.
  • 6E.L. Brancato, A pathway to Multifactor Aging, IEEE Transaction on Electrical Insulation28 (5) (1993) 820-825.
  • 7Piush Verma Condition monitoring of transformer oil and paper, Doctor Thesis~ Patiala, India, 2005.
  • 8FT-IR Spectroscopy Attenuated Total Reflectance (ATR) PerkinElmer technical note, available online at: http://las.perkinelmer.com/.
  • 9M. Trchovfi, Why do atoms vibrate in molecules? In Open science: practical courses from physical science and chemistry. [s.1.] " [s.n.], 2006, available online at:http://archiv.otevrena-veda.cz/users/Image/default/C 1Kttr zy/NH2006pdf/15.pdf.
  • 10J. Fahrenfort, Attenuated total reflection: A new principle for the production of useful infra-red reflection spectra of organic compounds, Spectrochimica Acta 17 (7) (1961) 698-709.

相关作者