期刊文献+

新型光纤式油膜厚度探测系统的研究 被引量:1

Research of Diagnostics System of Lubricant Film Thickness Using Fiber Optics
下载PDF
导出
摘要 激光诱导荧光法是近年来测试油膜厚度的新方法,本文分析了采用此法将光路暴露于空气中的油厚测试系统的不足之处,研制出光纤替代的油膜厚度探测系统。通过上述两种测试系统的对比试验,得出本文研制的新型光纤式油厚探测系统具有易于拆装、移动方便、信噪比高、测试稳定等特点。 Laser induced fluorescence technique is one of the effective methods to measure the oil film in recent years.The paper gives the drawbacks of the existed measuring system using laser induced fluorescence technique,laser rays exposed in the air,and presents an improved system by using fiber optic.The comparison test shows that signal to noise ratio was increased using new diagnostics system,which is also characterized by its easy installation,portable and compact structure,and good stability.
出处 《内燃机学报》 EI CAS CSCD 北大核心 1999年第4期379-382,共4页 Transactions of Csice
基金 上海市汽车工业总公司基金
关键词 激光诱导荧光 光纤 油膜厚度 测试系统 摩擦副 Laser induced fluorescence Fiber optics Lubricant film thickness Diagnostics system