期刊文献+

无源效率刻度技术在γ谱分析中的应用 被引量:14

Application of Sourceless Calibration Technology in Gamma Spectrum Analysis
下载PDF
导出
摘要 利用实验室无源效率刻度软件(LabSOCS)分析了样品形状、密度和成分对探测效率的影响,并计算给出了实验室γ谱仪探测效率与以上因子之间的关系。将LabSOCS计算的效率与标准体源刻度效率进行了比较,两者之间的相对偏差小于9%。对给定质量不同尺寸的圆柱状样品的γ探测效率进行了模拟计算,分析得到了砂土和空气样品的最佳几何尺寸;研究了高密度样品较强自吸收效应影响下,低能端和高能端射线在最佳制样尺寸下的探测效率变化趋势,最后对LabSOCS软件应用中应注意的问题提出了建议。 Different shape, density, material and ingredient of samples were simulated with LabSOCS, and their influence to the detection efficiency was analyzed. The relationship formula between the efficiency and different density was fitted to efficiency emendation. The comparison of efficiency between LabSOCS and standard body source showed that the relative deviation of efficiency was less than 9%. Through the simulation to cylindrical sample of different size, the best size was gained of which the detection efficiency of soil and air was best. The variety tendency of effiency of the best size in low gamma - ray energy and high gamma - ray energy was also studied in the influence of self - absorption to high - density sambles. In the end some advice to the application of the software LabSOCS was given.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2011年第1期39-43,共5页 Nuclear Electronics & Detection Technology
关键词 无源效率刻度 LabSOCS Γ谱分析 样品最佳尺寸 Sourceless Efficiency Calibration, LabSOCS, Gamma Spectrum Analysis,The Best Size of Sample
  • 相关文献

参考文献9

二级参考文献19

  • 1刘健.高纯锗γ谱仪对环境样品的效率刻度[J].核动力工程,1994,15(3):267-270. 被引量:5
  • 2虞彩琴.体源的γ射线自吸收校正[J].核技术,1994,17(12):742-745. 被引量:3
  • 3何宗慧.环境样品自吸收因子的计算和实验测定[J].辐射防护,1990,10(5):351-363. 被引量:14
  • 4郝润龙.体源自吸收校正方法[A]..中国计量科学研究院γ谱培训班教材[C].,1989..
  • 5Shakhashiro A,Gondin da Fonseca Azeredo A M,Sansone U,et al.Matrix Materials for Proficiency Testing:Optimization of a Procedure for Spiking Soil With Gamma-Emitting Radionuclides[J].Anal Bioanal Chem,2007,387(7):2 509-2 515.
  • 6Abdulghani Shakhashiro,Alexander Trinkl,Um-berto Sansone.The IAEA's ‘ALMERA Network' Proficiency Test on the Determination of Gamma-Emitting Radionuclides:A Test of Results Comparability[J].Appl Radiat Isot,2008,66:1 722-1 725.
  • 7Baronson F L.Validation of the Accuracy of theLabSOCS Software for Mathematical Efficiency Calibration of Ge Detectors for Typical Laboratory Samples[J].J Radioanal Nucl Chem,2003,255:137-141.
  • 8Lepy M C,Altzitzoglou T,Arnold D,et al.Intercomparison of Efficiency Transfer Software for Gamma-Ray Spectrometry[J].App Radiat Isotop,2001,55:493-503.
  • 9Judge SM, et al. The calibration of large area sources using a gamma-spectrometer[J]. Appl Radiat Isot, 1987, 38(10):865.
  • 10Vesic D, et al. Some practical aspects of gammaray spectroscopy of voluminous cylindrical sources with germanium detectors[J]. Nucl Instrum Methods, 1989, A276:216.