期刊文献+

Experimental Investigatin of Cementitious Slabs Rinforced with Wired-Meshes and Continuous CFRP Slices

Experimental Investigatin of Cementitious Slabs Rinforced with Wired-Meshes and Continuous CFRP Slices
下载PDF
导出
摘要 Bending tests were conducted on 23 ferrocement slab specimens with steel meshes and continuous CFRP fibers. Two, or three, or four CFRP slices are gathered as a rope and hence these ropes are arranged to form a grid tied to a skeletal frame. The three patterns of slice reinforcement were used to reinforce cementitious slabs with or without conventional wire mesh reinforcement. The slabs were square and simply supported at their periphery with a clear span of 400 mm, and concentrically patch loaded to failure. For specimens designed to fail in flexure, the specimens reinforced with CFRP slices showed a smoother load deflection response and higher flexural capacity. For slabs designed to fail in punching shear, adding CFRP slices showed significant improvement in the ultimate shear capacity and ductility over reference specimens. Well distributed fine cracks of smaller width than control specimens were developed and no matrix spalling was observed.
出处 《Journal of Civil Engineering and Architecture》 2010年第8期53-62,共10页 土木工程与建筑(英文版)
关键词 CFRP slices ferrocement slabs punching failure 碳纤维片 网板 碳纤维复合材料 碳纤维加固 胶凝 实验 弯曲试验 抗弯能力
  • 相关文献

参考文献9

  • 1ACI Committee 549, State-of-the-art report on ferrocement, ACI 549-R97, in: Manual of Concrete Practice, ACI, Detroit, 1997, p. 26.
  • 2ACI Committee 549-1R-88, Guide for design construction, and repair of ferrocement, ACI 549-1R-88 and 1R-93, in: Manual of Concrete Practice, ACI, Detroit, 1993, p. 27.
  • 3M. J. Shannag and T. B. Ziyyad, Flexural response of ferrocement with fibrous cementitious matrices, Construction and Building Materials 21 (2007) 1198-1205.
  • 4El Debs MK and A. E. Naaman, Bending behavior of mortar reinforced with steel meshes and polymeric fibers, Cement Concrete Composite 17 (4) (1995) 327-338.
  • 5O. Cengiz and L. Turanli, Comparative evaluation of steel mesh, steel fibre and high-performance polypropylene fibre reinforced shotcrete in panel test, Cement and Concrete Research 34 (2004) 1357-1364.
  • 6ESS No. 373, Portland Cement, Ordinary and Rapid Hardening, Egyptian Standard Specifications, Ministry of Industry, Cairo, 1991.
  • 7ECCS 203-2009, Egyptian Code of Practice for Design and Construction of Reinforced Concrete Structures (2nd ed.), 2009.
  • 8ESS No. 1108, Sand for Masonry Mortars, Egyptian Standard Specification, Ministry of Industry, Cairo, 1971.
  • 9ACI Committee 318, Building Code Requirements for Structural Concrete and Commentary, ACI, Farmington Hills, 2008.