摘要
介绍了500 kV紧凑型六分裂输电线路的结构特点、张力放线和附件安装等施工工艺以及在架线施工过程中遇到的一些具体问题,并给出了相应的解决办法。
This paper introduced the structural characteristics of the 6-split conductors of the 500 kV transmission line,and discussed the tension stringing process and processes of erection of line accessories.It tackles some obstacles in the tension stringing process and provides the corresponding solutions.
出处
《电网与清洁能源》
2010年第11期67-71,共5页
Power System and Clean Energy
关键词
500kV
六分裂导线
紧凑型
张力架线
施工工艺
500 kV
6-split conductor
compact pattern
tension stringing
construction process