期刊文献+

基于酶催化银沉积质量放大的血吸虫压电免疫传感器的研究 被引量:2

Studies of a Novel Mass Amplification Piezoelectric Immunosensor for Schistosoma-Japonicum Antibody Based on Enzymatic Catalyzation Deposition of Silver
原文传递
导出
摘要 发展了一种基于酶催化金属银沉积信号放大的新型高灵敏气相压电免疫传感检测技术.先将血吸虫抗原(SjAg)共价固定在石英晶体表面,制备得到血吸虫压电免疫传感器.检测时,在晶振上滴加不同浓度的待测血吸虫抗体,再将碱性磷酸酶标记的二抗通过夹心方式结合到传感器表面.然后利用碱性磷酸酶催化磷酸化的抗坏血酸酯水解从而还原硝酸银,使金属银沉积在晶振表面上,放大传感器的质量响应信号.实验结果表明该传感检测方法可显著提高气相压电免疫传感器的检测灵敏度,传感器对血吸虫抗体的响应线性范围在1~225 ng/mL,检测下限为1 ng/mL. A new mass amplification piezoelectric immunosensing method in gas phase was developed for the Schistosoma-Japonicum antibody(SjAb),which is based on the enzymatic catalyzation deposition of silver.On the surfaces of quartz crystals with a resonant frequency of 9 MHz,a molecular antigen of Schis-tosoma Japonicum(SjAg) was covalently immobilized via a self-assembly membrane of 2-mercaptoethylamine.By exposing the crystals to the SjAb solution and the alkaline phosphatase(ALP) labeled second antibody solution in turn,the ALP was bounded to the quartz crystal surfaces by a "sand-which" format,and it was then used as a biocatalyst for the hydrolyzation of 2-phospho-L-ascorbic acid to form the reductive ascorbic acid and further to yield mental silver deposit on the surfaces of quartz crystals,resulting in an amplified mass sensing effect.The sensing method is quite simple and sensitive,and the SjAb can be linearly determined in the range of 1~225 ng/mL,and the detection limit reaches as low as 1 ng/mL.
出处 《化学学报》 SCIE CAS CSCD 北大核心 2010年第23期2477-2481,共5页 Acta Chimica Sinica
基金 "863"计划项目(No.2009AA063004) 湖南省科技计划(No.2008GK3151)资助项目
关键词 银沉积 酶催化 气相压电传感器 日本血吸虫 silver deposition enzymatic catalyzation gas piezoelectric immunosensor Schisto-soma-Japonicum
  • 相关文献

参考文献15

  • 1Wu, Z.-Y.; Shen, G.-L.;Wang, S.-P.; Li, Z.-Q.; Yu, R.-Q. Anal. Chim. Acta 1999, 398(1), 57.
  • 2Wu, Z.-Y.; Yan, Y.-H.; Shen, G.-L.; Yu, R.-Q. Anal. Chim. Acta 2000, 412(1-2), 29.
  • 3王存嫦,王桦,吴朝阳,曾光明,黄国和,沈国励,俞汝勤.一种新的压电免疫传感器中生物分子固定化方法的研究[J].化学学报,2002,60(7):1284-1290. 被引量:13
  • 4Ebersole, R. C.; Ward, M. D. J. Am. Chem. Soc. 1988, 110(26), 8623.
  • 5Wu, Z. Y.; Wu, J.; Wang, S. P.; Shen, G. L.; Yu, R. Q. Bio- sens. Bioelectron. 2006, 22(2), 207.
  • 6Lowe, C. R. Biosensors 1985, 1, 3.
  • 7Turner, A. P. F. Sens. Actuators 1989, 17, 433.
  • 8Taylor, R. F. Bioinstrumentation: Research, Developments and Application, Butternorths, Boston, USA, 1990, p. 355.
  • 9Shons, A.; Dorman, F.; Najarian, J. J. Biomed. Mater. Res. 1972, 6, 565.
  • 10Ngeh-Ngwalubi, J.; Foley, P. H.; Kuan, S. S.; Guilbault, G. G. J. Am. Chem. Soc. 1986, 108, 5444.

二级参考文献5

共引文献13

同被引文献28

  • 1钟艳艳,王贵波,李宁,吴军.生物传感器现状与展望[J].重庆医学,2005,34(5):659-662. 被引量:8
  • 2赵广英,邢丰峰.鸡白痢电化学免疫传感器的研制[J].食品科技,2007,32(4):115-118. 被引量:6
  • 3蒋雪松,王剑平,应义斌,李延斌.用于食品安全检测的生物传感器的研究进展[J].农业工程学报,2007,23(5):272-277. 被引量:55
  • 4Wei H, Zhao Y K, Bi Y J, et al. Direct detection of Yersinia pestis from the infected animal specimens by a fiber optic biosensor[J]. Sons Actuator B-Chem, 2007, 123(1): 204-210.
  • 5Wang H J, Yuan R, Chai Y Q, et al. An uhrasensitive peroxydisulfate electrochemiluminescence immunosensor for Streptococcus suis serotype 2 based on L-cysteine combined with mimicking bi -enzyme synergetic catalysis to in situ generate coreactant[J]. Biosens Bioelectron, 2013, 43: 63-68.
  • 6Wang R H, Wang Y, Lassiter K, et al. Interdigitated array microelectrode based impedance immunosensor for detection of avian influenza virus H5N1[J]. Talanta, 2009, 79: 159-164.
  • 7Wang R H, Lin J H, Lassite K, et al. Evaluation study of a portable impedance biosensor for detection of avian influenza virus[J]. J Virol Methods, 2011, 178(1-2): 52-58.
  • 8Fan H, Ju P, Ai S. Controllable synthesis of CdSe nanostructures with tunable morphology and their application in DNA biosensor of Avian Influenza Virus [J]. Sens Actuator B-Chem,2010, 149(1 ):98-104.
  • 9Chang Y F, Wang S F, Huang J C, et al. Detection of swine- origin influenza A (H1N1) viruses using a localized surface plasmon coupled fluorescence fiber-optic biosensor [J]. Biosens Bioelectron,2010,26(3 ): 1068-1073.
  • 10Huang C H, Li J X, Tang Y, et al. Detection of duck hepatitis virus serotypel by biosensor based on imaging ellipsometry[J]. Curr Appl Phys, 2011, 11(3): 353-357.

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部