Quality Evaluation of Diffusion Bonded Joints by Electrical Resistance Measuring and Microscopic Fatigue Testing

Quality Evaluation of Diffusion Bonded Joints by Electrical Resistance Measuring and Microscopic Fatigue Testing
下载PDF
导出
摘要 Micro-structure related behavior of diffusion bonding joints is a crucial issue in device and reactor fabrication of Micro Chemo Mechanical Systems.However,the previous studies have been focused on the macro mechanical performance of diffusion bonded joint,especially diffusion bonding conditions effects on tensile strength,shearing strength and fatigue strength.The research of interfacial micro-voids and microstructures evolution for failure mechanism has not been carried out for diffusion-bonded joints.An interfacial electrical resistance measuring method is proposed to evaluate the quality of bonded joints and verified by using two-dimensional finite-element simulation.The influences of micro void geometry on increments of resistance are analyzed and the relationship between bonded area fraction and resistance increment is established by theoretical analysis combined with simulated results.Metallographic inspections and micro-hardness testing are conducted near the interface of diffusion bonded joints.For the purpose of identifying the failure mechanisms of the joints,both microscopic tensile and fatigue tests are conducted on the self-developed in-situ microscopic fatigue testing system.Based on the microscopic observations,the mechanism of interfacial failure is addressed.The observation result shows that for 316LSS diffusion-bonded joints,microstructure evolution and effect of micro-voids play a key role in interfacial failure mechanism.Finally,a new life prediction model in terms of the increment of electrical resistance is developed and confirmed by the experimental results.The proposed study is initiated that constituted a primary interfacial failure mechanism on micron scale and provide the life prediction for reliability of components sealed by diffusion bonding. Micro-structure related behavior of diffusion bonding joints is a crucial issue in device and reactor fabrication of Micro Chemo Mechanical Systems.However,the previous studies have been focused on the macro mechanical performance of diffusion bonded joint,especially diffusion bonding conditions effects on tensile strength,shearing strength and fatigue strength.The research of interfacial micro-voids and microstructures evolution for failure mechanism has not been carried out for diffusion-bonded joints.An interfacial electrical resistance measuring method is proposed to evaluate the quality of bonded joints and verified by using two-dimensional finite-element simulation.The influences of micro void geometry on increments of resistance are analyzed and the relationship between bonded area fraction and resistance increment is established by theoretical analysis combined with simulated results.Metallographic inspections and micro-hardness testing are conducted near the interface of diffusion bonded joints.For the purpose of identifying the failure mechanisms of the joints,both microscopic tensile and fatigue tests are conducted on the self-developed in-situ microscopic fatigue testing system.Based on the microscopic observations,the mechanism of interfacial failure is addressed.The observation result shows that for 316LSS diffusion-bonded joints,microstructure evolution and effect of micro-voids play a key role in interfacial failure mechanism.Finally,a new life prediction model in terms of the increment of electrical resistance is developed and confirmed by the experimental results.The proposed study is initiated that constituted a primary interfacial failure mechanism on micron scale and provide the life prediction for reliability of components sealed by diffusion bonding.
出处 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第2期187-194,共8页 中国机械工程学报(英文版)
基金 supported by National Natural Science Foundation of China(Grant No.50475068)
关键词 diffusion bonded joints interfacial failure electrical resistance microscopic fatigue testing diffusion bonded joints interfacial failure electrical resistance microscopic fatigue testing
  • 相关文献

参考文献18

  • 1KAZAKOV N F. Diffusion bonding of materials[M]. Oxford: Pergamon Press, 1985.
  • 2CHAKRABORTY I, TANG W C, BAME D P, et al. MEMS micro-valve for space applications[J]. Sensors and Actuators A, 2000, 83(1-3): 188-193.
  • 3McCREEDY T. Fabrication techniques and materials commonly used for the production of microreactors and micro total analytical systems[J]. Trends in Analytical Chemistry, 2000, 19(6): 396-401.
  • 4YU X H, TU S T, WANG Z D, et al. Development of a microchannel reactor concerning steam reforming of methanol[J]. Chemical Engineering Journal, 2006, 16(2): 123-132.
  • 5DAVE V R, HARTMAN D. A probabilistic diffusion weld modeling framework[J]. Welding Research, 2003, 82(7): 170-178.
  • 6DERBY B, WALLACH E R. Theoretical model for diffusion bonding[J]. Metal Science, 1982, 16(1): 49-56.
  • 7GHOSH M, SAMAR D, BANARJEE P S. Variation in the reaction zone and its effects on the strength of diffusion bonded titanium-stainless steel couple[J]. Materials Science and Engineering A, 2005, 390(1-2): 217-226.
  • 8BATRA I S, KALE G B, SAHA T K. Diffusion bonding of a Cu-Cr-Zr alloy to stainless steel and tungsten using nickel as an interlayer[J]. Materials Science and Engineering A, 2004, 369(1 2): 119-123.
  • 9POLANCO R, PABEOS A D, MIRANZO P. Metal-zeramic interfaces: joining silicon nitride-stainless steel[J]. Applied Surface Science, 2004, 238(1-4): 506-512.
  • 10NISHI H, ARAKI T. Low cycle fatigue strength of diffusion bonded joints of alumina dispersion-strengthened copper to stainless steel[J]. Journal of Nuclear Materials, 2000, 283:1 234-1 237.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部