摘要 充血性心力衰竭(congestive heart failure,CHF)是严重威胁人类生命的主要疾病,也是多种心血管疾病的终末表现。在先进的介入、手术及药物治疗的干预下,心律失常、急性心肌梗死等急性期患者生存率大大提高,但心力衰竭的发病率逐年升高,必须重视对心力衰竭的早期、正确的诊断和治疗,以延长患者的生命、改善其生活质量。最近的研究显示,
出处 《海军医学杂志》 2011年第1期60-62,共3页 Journal of Navy Medicine
基金 863课题资助项目(2007AA02Z437179)
  • 相关文献

参考文献15

  • 1Boldt J, Menges T, Wollbruck M, et al. Is continuous cardiac out- put measurement using the modilution reliable in the critically ill patient[J]. Crit Care Med, 1994, 22(5) : 1913 -1918.
  • 2Rocco M, Spadetta G, Morelli A, et al. A comparative evaluation of thermodilution and partial CO2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation [ J ]. Intensive Care Med, 2004, 30 (8) : 82 - 87.
  • 3Dark PM, Singer M. The validity of transesophageal Doppler ultrasono - graphy as a measure of cardiac output in critically ill adults [J]. Intensive Care Med, 2004, 30(5) : 2060 -2069.
  • 4Pierre S, Dominique D. Noninvasive cardiac output monitoring (NICOM) : a clinical validation [ J]. Intensive Care Med, 2007, 33(1): 1191 -1194.
  • 5Albert NM, Hail MD, Li J, et al. Equivalence of the bioimped-anceand the rmodilution methods in measuring cardiac output in hospitalizedpatients with advanced, decompnsated chronic heart failure[J]. Crit Care, 2004, 13(3) : 469 -479.
  • 6Peacock WF, Summers RL, Vogel J. Impact of impedance cardiography on diagnosis and therapy of emergent dyspnea: the ED - IMPACT trial[J]. Acad Emerg Med, 2006, 13(4) : 365 -371.
  • 7Engoren M, Baebee D. Comparison of cardiac output determined by bioimped ance, thermodilution, and the Fick method [ J ]. Crit Care, 2005, 14(11) : 40 -45.
  • 8Spiess B, Patel M, Sohow L, et al. Comparison of bioimpedance versus thermodilution cardiac output during cardiac surgery: evaluation of a second generation bioimpedance device[ J]. Cardiothorac Vasc Anesth, 2001, 15(3) : 567 -573.
  • 9Hanan K, Daniel B. Pierre S. Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance [ J ]. Physiol Heart Circ Physiol, 2007, 293 (5) : 583 - 589.
  • 10Myer J. Applications of cardiopulmonary exercise testing in the management of cardiovascular and pulmonary disease [J]. Sports Med, 2005, 26(3): 490-495.

同被引文献48

  • 1胡安义,梅尚文,陈生立,胡曙阳,谢玉程,杨章慧.心率震荡与慢性心力衰竭患者心功能、N末端脑钠肽前体的关系[J].中华临床医师杂志(电子版),2011,5(7):2066-2068. 被引量:2
  • 2CECCHINI S, SCHENA E, SACCOMANDI P, et al. Cardi- ac output estimation in mechanically ventilated patients: A comparison hetween prolonged expiration method and ther- modilution [C]//2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), San Diego, CA: 2012: 2708-2711.
  • 3CHEN Guo, MENG I.ingzhong, ALEXANDER B, et al. Comparison of noninvasive cardiac output measurements using the Nexfin monitoring device and the esophageal Doppler [J]. J Clin Anesth, 2012, 24(4): 275-283.
  • 4MAUS T M, REBER B, BANKS D A, et al. Cardiac output determination from endotracheally measured impedance cardi- ography: clinical evaluation of endotracheal cardiac output monitor[J]. JCardiothoracVascAnesth, 2011, 25(5): 770- 775.
  • 5DEKONINCK P, STEENHAUT P, VAN MIEGHEM T, et al. Comparison of Doppler-based and thret' dimensional meth- ods for fetal cardiac output measurement [J]. Fetal Diagn T- her, 2012, 32(1-2): 72-78.
  • 6SARACENI E, ROSSI S, PERSONA P, et al. Comparison of two methods for cardiac output measurement in critically ill patients[J]. BrJ Anaesth, 2011, 106(5): 690-694.
  • 7GASPARETTO N, CACCIAVILLANI I., VALENTE S. The accuracy of PiCCO measurements in hypothermic post cardiac arrest patients[J]. Anaesthesia, 2012, 67(9): 1050- 1051.
  • 8MOSLEHPOUR M, ZHANG Guanqun, MUKKAMALA R. Cardiac output monitoring by long time interval analysis of a radial arterial blood pressure waveform with correction for ar terial compliance changes using pulse transit time [C]//2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC. Boston, MA: 2011:5496-5498.
  • 9DABANLOO N J, ADAEI F, NASRABADI A M. The per- formanee of neural network in the estimation of cardiac output using arterial blood pressure waveforms [C]//2011 Compu- ting in Cardiology. Hangzhou: 2011 : 145-148.
  • 10GAMA DE ABREU M, WINKLER T, PAHLITZSCH T, et al. Performance of the partial CO2 rebreathing technique un- der different hemodynamic and ventilation/perfusion matching conditions [J]. Crit Care Med, 2003, 31(2): 543-551.