摘要
应用动量守恒原理,建立了U型过热器、再热器的理论模型,获得了包括结构尺寸和流动因子的特征参数M。依据M,U型过热器、再热器流动可分为三种状态,并依据实验数据,提出了U型过热器、再热器流量均布设计的基本原则和提高方向。
Based on the conservation of momentum, a theoretical model was introduced for U-type superheater or reheater. The analytical solution shows that there exist three flow states, depending on a general characteristic parameter,M. In accordance with the experimental data,the present paper indicates some basic principles and direction of design.
出处
《中国锅炉压力容器安全》
1999年第4期4-7,共4页
China Boiler and Pressure Vessel Safety