摘要
分析了形成亚临界电站锅炉过热器系统压降设计计算和实际运行值偏差的主要因素,提出了通过优化布置过热器系统来降低其流动阻力的具体方案。
Factors are analyzed based on fluid mechanics theory and comparison with test data, which effect resistant pressure drop of the superheater system in subcritical boilers. Optimal methods and practical scheme are presented to reduce resistance pressure drop of the superheater. Figs 2, tables 5 and refs 9.
出处
《动力工程》
CSCD
1999年第4期255-259,289,共6页
Power Engineering