期刊文献+

双窗K空间权重导航技术在3.0T磁共振冠脉成像中的应用(英文)

Dual-Window K-Space Weighted Gating Navigator Technique on Right Coronary MR Angiography at 3. 0 T
下载PDF
导出
摘要 提出了一种新的K空间权重导航技术(DKWN),该技术有利于缩短磁共振冠脉成像扫描时间同时获得好的图像质量。并将该导航技术应用到25位健康志愿者。经过实验分析,相比于常规固定窗导航技术而言,DKWN可以使导航效率提高30%(p<0.05),同时平均扫描时间由2.12 min缩短至1.64 min(p<0.05),并且图像质量相当。冠脉的直径和长度没有显著差异。 To shorten scanning time and increase the feasibility of experimental results, dual-window K-space weighted navigator technique (DKWN) on right coronary MR angiography at 3.0 T was implemented. The characteristics of DKWN technique and conventional navigator technique with fixed gating window in 25 normal subjects were evaluated. Compared to the conventional navigator sequence, DKWN sequences increase the scanning efficiency by 30% (p 〈 0. 05 ), while maintaining good image quality; further the corresponding scanning time decreases from 2.12 to 1.64 min (p 〈 0.05). The coronary artery lengths and diameters do not show statistically significant differences between the two techniques (p 〉 o. 05).
出处 《北京大学学报(自然科学版)》 EI CAS CSCD 北大核心 2011年第2期217-223,共7页 Acta Scientiarum Naturalium Universitatis Pekinensis
基金 国家自然科学基金(60871001)资助
关键词 MRI 3.0 T 运动抑制 K空间 导航 MRI 3.0 T motion suppression K-space navigator
  • 相关文献

参考文献25

  • 1Lieberman J M, Botti R E, Nelson A D. Magnetic resonance imaging of the heart. Radiol Clin North Am, 1984, 22:847-858.
  • 2Pruessmann K P, Weiger M, Scheidegger M B, et al. SENSE: sensitivity encoding for fast MRI. Magn Reson Med, 1999, 42:952-962.
  • 3Sehmitt M, Potthast A, Sosnovik D E, et al. A 128channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Tesla. Magn Reson Med, 2008, 59: 1431-1439.
  • 4Stuber M, Botnar R M, Fischer S E, et al. Preliminary report on in vivo coronary MRA at 3 Tesla in humans. Magn Reson Med, 2002, 8:425-429.
  • 5Huber M E, Kozerke S, Pruessmann K P, et al. Sensitivity-encoded coronary MRA at 3T. Magn Reson Med, 2004, 52:221-227.
  • 6Fuderer M. The information content of MR images. IEEE Trans Med Imaging, 1988, 7:368-380.
  • 7Sachs T S, Meyer C H, Irarrazabal P, et al. The diminishing variance algorithm for real-time reduction of motion artifacts in MRI. Magn Reson Med, 1995, 34: 412-422.
  • 8Jhooti P, Gatehouse P D, Keegan J, et al. Phase ordering with automatic window selection (PAWS) : a novel motion-resistant technique for 3D coronary imaging. Magn Reson Med, 2000, 43:470-480.
  • 9Weiger M, Boernert P, Proksa R, et al. Motion adapted gating based on K-space weighting for reduction of respiratory motion artifacts// Proc 4th Annual Meeting of ISMRM. New York, 1996:302.
  • 10Weiger M, Boernert P, Proksa R, et al. Motion-adaptedgating based on K-space weighting for reduction of respiratory motion artifacts. Magn Reson Med, 1997, 38:322-333.