期刊文献+

Carto指导环肺静脉电隔离治疗阵发性房颤的疗效观察

The efficacy of circumferential pulmonary vein isolation by Carto guiding in paroxysmal atrial fibrillation
下载PDF
导出
摘要 目的 观察Carto系统指导下环肺静脉隔离治疗阵发性房颤的临床疗效.方法 采用Carto系统构建肺静脉及左房三维电解剖图,在Carto指导下行环肺静脉线性消融.结果 5例阵发性房颤中,4例即刻转复窦律,1例在随访2个月时转复窦律.结论 Carto系统指导下环肺静脉隔离治疗阵发性房颤是安全有效的. Objective To investigate the effectiveness and advantages of the Carto technique inguiding catheter ablation in paroxysmal atrial fibrillation. Methods The carto system was used to generate 3 D electroanatomic left atrial maps. The left atrial linear ablation were performed. Results 4 patients with persistent AF converted to sinus rhythm, 1 patient was converted to sinus rhythm 2 months later. Conclusion Carto technique have been proofed safety and effectiveness.
出处 《中国心血管病研究》 CAS 2011年第2期128-129,共2页 Chinese Journal of Cardiovascular Research
关键词 导管消融 心房颤动 CARTO系统 Catheter ablation Atrial fibrillation Carto system
  • 相关文献

参考文献6

二级参考文献35

  • 1马坚,方丕华,楚建民,贾玉和,张澍,黄从新.环肺静脉口部线性消融治疗心房颤动的初期体会[J].中华心律失常学杂志,2005,9(2):100-104. 被引量:10
  • 2吴书林,李海杰,郑祥生,欧阳非凡,尹滔业,孙家珍,冯建章.射频消蚀术治疗房性心动过速[J].中华心血管病杂志,1995,23(1):25-27. 被引量:18
  • 3杨平珍,吴书林,詹贤章,李海杰,方咸宏.Carto系统与常规X线下电生理标测射频消融治疗房性心动过速的临床研究[J].中华心律失常学杂志,2006,10(2):135-137. 被引量:3
  • 4Marchlinski F,Callans D,Gottlieb c.Magnetic electroanatomical mapping for ablation of focal atrial tachycardias.PACE,1998,21:1621-1635.
  • 5Kalman JM,Vanhare GF,Olgin JE,et al.Ablation of "incisional"reentrant atrial tachycardia complicating surgery for congential heart disease.Use of entrainment to define a critical isthmus of conduction.Circulation,1996,93:502-512.
  • 6Lukac P,Pedersen AK,Mortensen PT.Ablation of atrial tachycardia after surgery for congenital and acquired heart disease using an electroanatomic mapping system:Which circuits to expect in which substrate? Heart Rhythm,2005,2:64-72.
  • 7Tanner H,Lukac P,Schwich N,Irrigated-tip catheter ablation of intraatrial reentrant tachycardia in patients late after surgery of congenital heart disease.Heart Rhythm,2004,1:268-275.
  • 8Leonelli FM,Tomassoni G,Richey M.Ablation of incisional atrial tachycardias using a three-dimensional nonfluoroscopic mapping system.PACE,2001,24:1653-1659.
  • 9Ben-Haim SA, Osadchy D, Schuster I, et al. Nonfluoroscopic, in vivo navigation and mapping technology. Nat Med, 1996, 2 : 1393- 1395.
  • 10Gepstein L, Hayam G, Ben-Haim SA. A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results. Circulation, 1997, 95: 1611- 1622.

共引文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部