摘要
针对电弧炉燃烧—碘量法测定钢铁中碳硫过程中出现的硫含量不稳定的现象,通过试验比较得到是因为粉尘太多导致吸附严重影响测定结果的结论。
In the light of the phenomenon that the sulfur content is unstable in the measurement of carbon and sulfur in steel and iron with electric arc furnace combustion-iodometry method,and through the test and comparison,this paper draws a conclusion that the measured results are influences by the serious adsorption caused by the too much dust.
出处
《科技情报开发与经济》
2011年第5期194-195,共2页
Sci-Tech Information Development & Economy
关键词
硫测定
电弧炉燃烧
碘量法
measurement of sulfur content
electric arc furnace combustion
iodometry method