期刊文献+

Gas Sensitivity of Poly (3, 4-ethylene dioxythiophene) Prepared by a Modified LB Film Method

Gas Sensitivity of Poly (3, 4-ethylene dioxythiophene) Prepared by a Modified LB Film Method
下载PDF
导出
摘要 An arachidic acid/poly (3, 4-ethylene dioxythiophene) (AA/PEDOT) multilayer Langmuir-Blodgett (LB) film was prepared by a modified LB film method. The theories were utilized to explain the effects between HCl molecule and LB film. The gas sensitivity mechanism of poly (3, 4-ethylene dioxythiophene) (PEDOT) multilayer film can be explained by the charge transfer between p system of PEDOT and oxidization HCl system. The gas sensitivity of PEDOT LB film deposited interdigital electrode to HCl was tested. The results showed that film thickness, treating temperature, deposition speed had different influence on film gas sensitivity. The AA/PEDOT film deposited device exhibited nonlinear behavior to HCl gas at lower concentration (20-60 ppm) and linear response behavior at higher gas concentration was observed. The time of the compound LB film of the AA/PEDOT responding to the 30 ppm HCl gas is about 20 seconds, which is far quicker than the time of the film to the PEDOTPRESS film(about 80 seconds). It is not higher film press to better film. When the film press attains 45 mNs/m, the sensitivity of the AA/PEDOT film on the contrary descends. An arachidic acid/poly (3, 4-ethylene dioxythiophene) (AA/PEDOT) multilayer Langmuir-Blodgett (LB) film was prepared by a modified LB film method. The theories were utilized to explain the effects between HCl molecule and LB film. The gas sensitivity mechanism of poly (3, 4-ethylene dioxythiophene) (PEDOT) multilayer film can be explained by the charge transfer between p system of PEDOT and oxidization HCl system. The gas sensitivity of PEDOT LB film deposited interdigital electrode to HCl was tested. The results showed that film thickness, treating temperature, deposition speed had different influence on film gas sensitivity. The AA/PEDOT film deposited device exhibited nonlinear behavior to HCl gas at lower concentration (20-60 ppm) and linear response behavior at higher gas concentration was observed. The time of the compound LB film of the AA/PEDOT responding to the 30 ppm HCl gas is about 20 seconds, which is far quicker than the time of the film to the PEDOTPRESS film(about 80 seconds). It is not higher film press to better film. When the film press attains 45 mNs/m, the sensitivity of the AA/PEDOT film on the contrary descends.
作者 郑华靖
出处 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2011年第1期70-74,共5页 武汉理工大学学报(材料科学英文版)
基金 Funded by the National Natural Science Foundation of China (No.60372002)
关键词 poly (3 4-ethylene dioxythiophene) (PEDOT) Langmuir-Blodgett (LB) film method gas sensitivity measurement poly (3 4-ethylene dioxythiophene) (PEDOT) Langmuir-Blodgett (LB) film method gas sensitivity measurement
  • 相关文献

参考文献5

二级参考文献111

共引文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部