摘要
分析了低温液体输入热管道后升压过程, 并对输送过程中的临界质量流进行了计算, 结合有关文献的实验数据, 给出输送过程中的压力计算公式。并提出了减少压力最大值的方法, 对于低温液体输送参数的确定、管道的设计提供参考。
In this paper the progress of pressure rising for cryogenic liquid in the heated pipe was analyzed and the critical mass flow velocity in the transfer process was calculated.According to the experimental data in some literatures,the calculation formula of the pressure in this transfer process was proposed.The ways to reduce the maximum pressure were also proposed in this paper.It provided the reference to determine the parameter in transferring cryogenic liquid and to design the pipes.
出处
《低温工程》
CAS
CSCD
北大核心
1999年第4期154-158,共5页
Cryogenics
关键词
低温液体
输送
热管道
升压过程
cryogenic liquid
transfer
hot pipe
pressure rising