摘要 Three vaned diffusers, designed to have high negative incidence (-8°) at the design operating point, are studied experimentally. The overall performance (efficiency and pressure ratio) are measured at three rotational speeds, and flow angles before and after the diffuser are measured at the design rotational speed and with three mass flow rates. The results are compared to corresponding results of the original vaneless diffuser design. Attention is paid to the performance at lower mass flows than the design mass flow. The results show that it is possible to improve the performance at mass flows lower than the design mass flow with a vaned diffuser designed with high negative incidence. However, with the vaned diffusers, the compressor still stalls at higher mass flow rates than with the vaneless one. The flow angle distributions after the diffuser are more uniform with the vaned diffusers.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2011年第2期97-105,共9页 热科学学报(英文版)
基金 the financial support of the Academy of Finland, the Finnish Funding Agency for Technology and Innovation - TEKES, and Cardo Production Finland Oy (former High Speed Tech Oy Ltd.)
关键词 centrifugal compressor vaned diffuser efficiency PERFORMANCE flow field 离心压缩机 扩散器 级性能 发病率 设计工作 叶片扩压器 旋转速度 质量流量
  • 相关文献

参考文献21

  • 1International Energy Agency,2008, Energy Technology Perspectives 2008-Scenarios and Strategies 2050.
  • 2Hohlweg, W., Direnzi, L. and Aungier R., 1993. ,,Com-parison of Conventional and Low Solidity Vaned Diffus-ers”. In 93-GT-98, International Gas Turbine and Aero-engine Congress and Exposition, ASME.
  • 3He, N. and Tourlidakis, A, 2001, “Analysis of Diffuserswith Different Number of Vanes in a Centrifugal Com-pressor Stage”. In 2001-GT-0321,ASME Turbo Expo.
  • 4Kim, W. and Engeda A., 1997. “Comparison of Pressure Recovery and Overall Performance of Different Diffusers for Centrifugal Compressor”. In FEDSM97-3029 Fluids Engineering Division Summer Meeting, ASME.
  • 5Engeda A., 1998. “Design and Investigation of Four Low Solidity Vaned Diffusers to Assess the Effect of Solidity and Vane Number.” In 98-GT-252, International Gas Tur-bine and Aeroengine Congress and Exhibition, ASME.
  • 6Engeda, A., 2003. “Experimental and numerical investi-gation of the performance of 240 kW centrifugal com- pressor with different diffusers”. Experimental Thermal and Fluid Science 28,55-72.
  • 7Kim, Y., Engeda, A., Aungier, R. and Amieni, N., 2002. “A centrifugal compressor stage with wide flow range vaned diffuser and different inlet configurations”. Pro-ceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy,216,307-320.
  • 8Issac, J., Sitararn, N. and Govardhan, M., 2003. “Per-formance and wall static pressure measurements on cen-trifugal compressor diffusers”. Proceedings of the Institu-tion of Mechanical Engineers, Part A: Journal of Power and Energy,217,547-558.
  • 9Clements, W. and Artt, D., 1989. “The Influence of Dif- fuser Vane Leading Edge Geometry on the Performance of a Centrifugal Compressor”. In 89-GT-169, Gas Tur-bine and Aeroengine Congress and Exposition, ASME.
  • 10Shum, Y., Tan, C. and Cumpsty, N., 2000. “Impeller-dif-fuser interaction in a centrifugal compressor”. Journal of Turbomachinery,122, 777-786.