期刊文献+

比较新型3D-T2 FLAIR序列与传统SE T1W、3D-SPGR、2D-T2 FLAIR序列的强化效果 被引量:11

Comparing the enhancement effect of new 3D-T2 FLAIR sequence with conventional SE T1W,3D-SPGR and 2D-T2 FLAIR sequences
下载PDF
导出
摘要 目的分析比较新型三维容积液体衰减反转恢复(3D-T2 FLAIR)序列与传统自旋回波T1加权(SE T1 W)序列、三维容积扰相梯度回波(3D-SPGR)序列、二维液体衰减反转恢复(2D-T2 FLAIR)序列在不同浓度对比剂时的强化效果。方法将10只装有不同浓度对比剂的塑料试管按浓度由低到高顺序排列,在相同扫描序列和参数下采集10只试管和10名志愿者的头颅图像。计算图像信号的增强对比度(CER)、信号增强程度(SED)以及信号增强率(SER),绘制浓度-信号增强对比度关系曲线、浓度-信号增强程度关系曲线及浓度-信号增强率关系曲线。分析比较各个序列在不同浓度对比剂时的强化效果。结果新型3D-T2 FLAIR序列的CER及SED在低浓度的对比剂时较传统SE T1 W、3D-SPGR、2D-T2 FLAIR序列高,而在高浓度时CER及SED较传统SE T1 W、3D-SPGR、2D-T2 FLAIR序列低;新型3D-T2 FLAIR序列的SER较传统SE T1 W、3D-SPGR、2D-T2 FLAIR序列低。结论新型3D-T2 FLAIR序列在常规剂量及更低剂量扫描中具有较大的临床应用价值,但肉眼观察对于新型3D-T2 FLAIR序列增强效果的敏感性较低。 Objective To compare the enhancement effect of the new three dimensional fluid-attenuated inversion recovery(3D-T2 FLAIR) sequence with conventional spin echo T1 weighted(SE T1W),three dimensional spoiled gradient recalled(3D-SPGR) and two dimensional fluid-attenuated inversion recovery(2D-T2 FLAIR) sequences at different concentrations of contrast agent.Methods Ten plastic tubes filling with gadopentetate dimeglumine(Gd-DTPA) in different concentrations were prepared and arranged according to different concentrations.Ten plastic tubes and volunteers were scanned with the same sequence and parameters.Images' contrast enhancement ratio(CER),single enhancement degree(SED) and single enhancement rate(SER) were calculated,then concentrations-contrast enhancement ratio curve,concentrations-signal enhancement degree curve,concentrations-signal enhancement rate curve were drawed and the contrast enhancement effect of each sequences at different concentrations were analyzed.Results CER and SED of the new 3D-T2 FLAIR sequence were higher than conventional SE T1W,3D-SPGR,2D-T2 FLAIR sequences at lower dose,but were lower than those of conventional SE T1W,3D-SPGR,2D-T2 FLAIR sequences at higher dose.SER of the new 3D-T2 FLAIR sequence was lower than conventional SE T1W,3D-SPGR and 2D-T2 FLAIR sequences at any concentrations.Conclusion New 3D-T2 FLAIR sequence has great potential value in clinical practice at conventional dose and lower,but with a less sensitivity with naked eye.
出处 《中国医学影像技术》 CSCD 北大核心 2011年第3期622-626,共5页 Chinese Journal of Medical Imaging Technology
关键词 磁共振成像 信号增强程度 增强对比度 信号增强率 三维容积液体衰减反转恢复序列 Magnetic resonance imaging Signal enhancement degree Contrast enhancement ratio Signal enhancement rate Three dimensional fuid-attenuated inversion recovery sequence
  • 相关文献

参考文献9

  • 1Plewes DB, Bishop J. Spin-echo MR imaging//Bronskill M, Sprawls P. The physics of MRI: 1992 AAPM summer schoolproceedings. New York: American Association of Physicists in Medicine, 1993 : 166-187.
  • 2Bradley WG, Yuh WTC, Bydder GM. Use of MR contrast agents in the brain//Bradley WG, Bydder GM. Advanced MR imaging techniques. London: Martin Dunitz, 1997 : 183-193.
  • 3Busse RF, Hariharan H, Vu A, et al. Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedulesand generation of clinical T2 contrast. Magn Reson Med, 2006, 55 (5) : 1030-1037.
  • 4周正荣,彭卫军,沈天真,陈星荣.增强后液体衰减反转恢复序列MRI在颅内肿瘤诊断中的应用[J].中华放射学杂志,2005,39(12):1242-1246. 被引量:18
  • 5Tsuchiya K, Katase S, Yoshino A, et al. Preand postcontrast FLAIR MR Imaging in the diagnosis of intracranial meningeal patholo gy. Radiat Med, 2000,18(6) :363 368.
  • 6Terae S, Yoshida D, Kudo K, et al. Contrastenhanced FLAIR ima ging in combination with pre and postcontrast magnetization transferTl-weighted imaging: usefulness in the evaluation of brain metastases. J Magn Reson Imaging, 2007,25(3):479-487.
  • 7Carmichael DW, Thomas DL, Ordidge RJ, et al. Reducing ghosting due to k-space discontinuities in fast spin echo (FSE) imaging by anew combination of k space ordering and parallel imaging. J Magn Reson, 2009,200(1) :119-125.
  • 8郑君惠,梁长虹,罗维.高场磁共振射频能量吸收率SAR的研究[J].中国医学影像技术,2008,24(9):1469-1472. 被引量:9
  • 9Ercan N, Guhekin S, Celik H, et al. Diagnostic value of contrast enhanced fluid-attenuated inversion recovery MR imaging of intracranial metastases. AJNR Am J Neuroradiol, 2004,25(5) :761-765.

二级参考文献15

  • 1牛中奇,侯建强,周永军,王海彬,卢智远.生物电磁剂量学及人体吸收电磁剂量的数值分析[J].中国生物医学工程学报,2006,25(5):580-584. 被引量:15
  • 2Zimmerman RA,Gibby WA,Carmody RF.Neuroimaging:clinical and physical principles.New York:Springer-Verlag,2000.313-364.
  • 3Hajnal JV,Bryant DJ,Kasuboski I,et al.Use of fluid attenuated inversion recovery(FLAIR) pulse sequences in MRI of the brain.J Comput Assist Tomogr,1992,16:841-844.
  • 4Husstedt HW,Sickert M,K stler H,et al.Diagnostic value of the fast-FLAIR sequence in MR imaging of intracranial tumors.Eur Radiol,2000,10:745-52.
  • 5Singh SK,Agris JM,Leeds NE,et al.Intracranial leptomeningeal metastases:comparison of depiction at FLAIR and contrast-enhanced MR imaging.Radiology,2000,217:50-53.
  • 6Mathews VP,Caldemeyer KS,Lowe MJ,et al.Brain:gadolinium-enhanced fast fluid-attenuated inversion-recovery MR imaging.Radiology,1999,211:257-263.
  • 7Essig M,Knopp MV,Schoenberg SO,et al.Cerebral gliomas and metastases:assessment with contrast-enhanced fast fluid-attenuated inversion-recovery MR imaging.Radiology,1999,210:551-557.
  • 8Essig M,Schoenberg SO,Debus J,et al.Disappearance of tumor contrast on contrast-enhanced FLAIR imaging of cerebral gliomas.Magn Reson Imaging,2000,18:513-518.
  • 9Griffiths PD,Coley SC,Romanowski CA,et al.Contrast-enhanced fluid-attenuated inversion recovery imaging for leptomeningeal disease in children.AJNR,2003,24:719-723.
  • 10Ercan N,Gultekin S,Celik H,et al.Diagnostic value of contrast-enhanced fluid-attenuated inversion recovery MR imaging of intracranial metastases.AJNR,2004,25:761-765.

共引文献25

同被引文献56

引证文献11

二级引证文献55

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部