采用自主开发的表面改性新技术——改进表面热处理(PTO)技术对医用钛材料进行表面处理,然后采用扫描电镜、X射线衍射等手段分析其表面改性层,并进行生物学评价.结果表明,PTO表面改性钛植入物具有良好的生物相容性和优异的血液相容性,其综合性能达到或超过国家标准GB/T16886的要求.
New surface modifications of titanium for medical application have been carried out by a self-developed technique, namely promoted thermal oxidation (PTO). PTO-treated surface layers was analyzed using scanning electron microscopy (SEM) and X-ray diffraction (XRD), and the biocompatibility and hemocompatibility of the PTO-treated titanium were evaluated. The results show that the PTO-modified titanium implants are characterized by good biocompatibility and excellent hemocompatibility, and the comprehensive performance reaches or exceeds the national standard GB/T16886.
出处
《材料研究与应用》
CAS
2011年第1期27-30,共4页
Materials Research and Application
基金
国家科技型中小企业技术创新基金项目(07C26214401798)
广东省科技计划项目(2009B011000009)
广州市技术创新基金项目(2007V43C0011)
广州开发区科技计划项目(2008G-P117
2010S-P092)
关键词
医用钛材料
表面改性
应用
生物相容性
血液相容性
titanium
surface modification
application
biocompatibility
hemocompatibility