摘要 背景:行CT血管成像时,需要静脉注入碘对比剂,并且随着对比剂应用剂量的增大,对患者带来的危害也相应增大。目的:验证低剂量对比剂在多层螺旋CT肺动脉成像中的可行性。方法:12只健康家犬参照临床上人的碘海醇(300mgI/mL)使用剂量,根据《药理实验中动物间和动物与人体间的等效剂量换算》得出相应犬的3个剂量组分别为碘海醇2.40mL/kg,2.02mL/kg,1.62mL/kg组。12只犬分别接受3种剂量各1次,每次实验扫描间隔时间至少48h,共进行36次CT扫描。根据原始图像、容积重现像和最大密度投影像,对3种方案肺动脉分支的显示情况、肺动脉边缘清晰程度及肺静脉充盈程度进行评分,并测量肺动脉内对比剂的浓度。结果与结论:3种方案均能清晰显示犬肺动脉4级分支,血管边缘清晰,显示程度评分各组差异无显著性意义(P>0.05)。3种方案肺静脉显影程度均较低,与肺动脉有很好的密度对比,各组差异无显著性意义(P>0.05)。3种方案肺动脉内的对比剂浓度均维持在较高的水平,差异无显著性意义(P>0.05)。提示低剂量对比剂在多层螺旋CT犬肺动脉成像中是可行的,图像质量可以满足临床诊断要求,从而为临床应用低剂量对比剂行肺动脉成像提供实验依据。 BACKGROUND:CT angiograph needs that the contrast media injects into vein,and the greater the dose of contrast media,the greater the hazard to patients.OBJECTIVE:To validate the feasibility of low dose contrast media in spiral CT pulmonary artery angiograph.METHODS:A total of 12 healthy canis familiaris with reference to iohexol dose of human in clinic,according to "equivalent dose conversion of animals and between animals and humans in pharmacological experiments",which got the corresponding three dose groups:iohexol 2.40mL/kg group,iohexol 2.02mL/kg group,iohexol 1.62mL/kg group.Twelve canis familiaris were treated with 3 kinds of doses for once;scan interval of each experiment was at least 48 hours,a total of 36 CT scans.Pulmonary artery branch conditions,pulmonary vein edge clarity,and filling degree of pulmonary vein of 3 proposals were scored by original image,volume recurrence image,and maximum intensity projection image,and the concentration of contrast media in pulmonary artery was measured RESULTS AND CONCLUSION:Three kinds of proposals can clearly show 4 branches of canines' pulmonary artery,the edge of vascular is clear.There was no significant difference in each group (P0.05).The degree of pulmonary vein imaging was lowered,and had a good density comparison with pulmonary artery;there was no significant difference in each group (P0.05).The concentration of contrast media in pulmonary artery maintained at a high level,there was no significant difference (P0.05).It is indicated that it is feasible to use low dose contrast media in multislice spiral CT pulmonary artery angiograph of canines,the image quality can meet the clinical diagnostic requirements to provide the experimental basis of pulmonary artery angiograph with low dose contrast media for clinical application.
出处 《中国组织工程研究与临床康复》 CAS CSCD 北大核心 2011年第4期671-674,共4页 Journal of Clinical Rehabilitative Tissue Engineering Research
基金 辽宁省自然科学基金项目(2009526) 课题名称:低浓度低剂量碘对比剂降低肾脏损害的实验研究~~
  • 相关文献

参考文献15

  • 1Remy-Jardin M, Remy J.Spirat CT angiography of the pulmonary circulation. Radiology.1999;212(3):615-636.
  • 2Ellis JH, Cohan RH. Reducing the risk of contrast-induced nephropathy: a perspective on the controversies.A JR Am J Roentgenol. 2009; 192(6): 1544-1549.
  • 3黄继汉,黄晓晖,陈志扬,郑青山,孙瑞元.药理试验中动物间和动物与人体间的等效剂量换算[J].中国临床药理学与治疗学,2004,9(9):1069-1072. 被引量:1362
  • 4Marenzi G, Lauri G, Assanelli E,et al. Contrast-induced nephropathy in patients undergoing primary angioplasty for acute myocardial infarction. J Am Coil Cardiol. 2004;44 (9): 1780-1785.
  • 5Dangas G, Lakovou I, Nikolsky E, et al. Contrast-induced nephropathy after percutaneous coronary interventions in relation to chronic kidney disease and hemodynamic variables. Am J Cardiol. 2005;95(1):13-19.
  • 6Rihal CS, Textor SC, Grill DE, et al. Incidence and prognostic importance of acute renal failure after percutaneous coronary intervention. J Circulation. 2002; 105(19):2259-2264.
  • 7Thomsen HS. Guidelines for contrast media from the European society of urogen tal radioloqy. A JR. 2003;181(6): 1463-1471.
  • 8殷月慧,王荣芳,孙希芹,王文刚.双源CT肺动脉栓塞低剂量高浓度优维显对比剂的应用[J].医疗装备,2009,22(6):51-52. 被引量:4
  • 9Hopper KD, Mosher T J, Kasales C J, et al. Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector. Radiology. 1997;205(1 ):269-271.
  • 10Matsumoto M, Kasuya H, Sato T, et al. Can 3D-CT angiography (3D-CTA) replace conventional catheter angiography in ruptured aneurysm surgery? Our experience with 162 cases. Fukushima J Med Sci. 2007:53(2):85-94.

二级参考文献22

  • 1蔡欣,邓宇.多层螺旋CT在肺栓塞诊断中的应用[J].中国医学影像技术,2005,21(4):562-564. 被引量:22
  • 2张燕,金征宇,张竹花,赵文敏,王沄,朱海峰,梁继祥,陆菁菁,薛华丹.多层螺旋CT对周围肺动脉显示能力的研究[J].临床放射学杂志,2005,24(10):879-884. 被引量:28
  • 3[4]ww.fda.gov/cder/cancer/animalframe.htm
  • 4[5]FDA Guidance for industry and reviewers: Estimating the safe starting dose in clinical trials for therapeutics in adult healthy volunteers[ S]. 2002; 12
  • 5[6]FDA Guidance for Industry: food-effect bioavailability and fed bioequivalence studies[ S]. 2002; 12
  • 6Remy-Jardin M,Mastora I,Remy J.Pulmonary emboius imaging with multislice CT[J].Radiol Clin North Am,2003,41(31):507-519.
  • 7Stock KW,Remy-Jardin M.Pulmonary embolism:treatment with thrombus fragmentation and local fibrinolysis with recombinant human tissue plasminogen activator[J].Cardiovasc Intervent Radiol,1997,20(5):364-368.
  • 8Woodard PK,Sostmen HD,MacFall JR,et al.Detection of pulmonary embolism:comparison of contrast-enhanced spiral CT and time-of-flight MR technique[J].J Thorac Imaging,1995,10(1):59-72.
  • 9Remy-Jardin M,Remy J.Spiral CT angiography of the pulmonary circulation[J].Radiology,1999,212(3):615-636.
  • 10Schoepf UJ,Holzknecht N,Helmberger TK,et al.Subsegmental pulmonary emboli:improved detection with thirrcollimation multidetector row spiral CT[J].Radiology,2002,222(2):483-490.