期刊文献+

金对金解剖直径头微创全髋关节置换术治疗高龄股骨颈骨折的近期疗效对照研究 被引量:3

Control study of short-term curative effect of minimally invasive total hip arthroplasty using metal-on-metal large-diameter femoral head for the elderly patients with femoral neck fractures
下载PDF
导出
摘要 目的探讨金对金解剖直径头和常规小直径头(28mm)全髋关节置换(total hip arthroplasty,THA)微创技术治疗高龄股骨颈骨折患者的临床疗效。方法 2006年1月至2007年12月间因股骨颈骨折在我中心行微创全髋关节置换手术并获得完整资料的高龄(>70岁)患者61例61髋,其中采用常规直径头股骨头全髋关节假体(对照组)30例30髋,采用金对金大直径股骨头全髋关节假体(观察组)31例31髋。分析两组术后2周、6周髋关节活动范围,术后2年假体脱位率以及Harris评分结果的差异。结果术后对照组脱位2例6次,观察组0例。观察组的Harris评分优秀率高于对照组;术后2周(除后伸动作外)和6周的髋关节活动度均大于对照组,两组比较,差异有统计学意义(P<0.05)。结论采用金对金解剖直径头THA微创技术治疗高龄股骨颈骨折患者,具有术后早期髋关节稳定性提高、主动活动范围增加、术后脱位率降低等优点,近期疗效满意。 Objective To discuss the postoperative curative effects of two surgical techniques of minimally invasive total hip arthroplasty (THA) using metal-on-metal large-diameter and conventional diameter femoral head for the elderly patients with femoral neck fractures. Method From January 2006 to December 2007, 61 elderly patients (70 years old) with 61 hips obtained minimally invasive THA for femoral neck fractures in our center. Those patients were divided into the control group (30 cases 30 hips with THA using standard 28 mm diameter femoral head) and the experimental group (31 cases 31 hips with THA using metal-on-metal large-diameter femoral head). The range of motion of hip at 2 and 6 weeks after operation, the prothesis dislocation rate and Harris score after 2 years' follow-up were compared between two groups. Results In control group, dislocation occurred in 2 cases for 6 times while no dislocation happened in experimental group. Compared with control group, the excellent rate of Harris score was higher and the range of motion of hip at 2 weeks(except posterior extension) and 6 weeks after operation were better. There was statistically difference between two groups (P 0.05). Conclusion Minimally invasive THA with metal-on-metal large diameter femoral head prothesis has been proved to obtain satisfactory short-term curative effects which could improve the stability of hip during early postoperative period, increase the range of active motion and reduce the incidence of postoperative dislocation.
出处 《中国骨科临床与基础研究杂志》 2010年第4期254-260,共7页 Chinese Orthopaedic Journal of Clinical and Basic Research
关键词 关节成形术 置换 股骨颈骨折 髋假体 老年人 Arthroplasty replacement hip Femoral neck fractures Hip prosthesis Aged
  • 相关文献

参考文献1

二级参考文献2

共引文献15

同被引文献22

  • 1张先龙,何耀华,王琦,蒋垚,曾炳芳.后路小切口人工全髋关节置换术[J].中华创伤杂志,2005,21(8):591-594. 被引量:30
  • 2黄杰,马玉敏.3例Ⅰ期腰髋同时手术患者的围手术期护理[J].中华护理杂志,2005,40(8):582-583. 被引量:9
  • 3Malviya A, Ramaskandhan J, Holland JP, et al. Metal-on-metal total hip arthroplasty. J Bone Joint Surg Am, 2010, 92 : 1675- 1683.
  • 4Dowson D, Hardaker C, Flett M, et al. A hip joint simulator study of the performance of metal-on-metal joints. Part I -The role of materials. 3 Arthroplasty, 2004, 19 : 118 - 123.
  • 5Amstutz HC, Beau|e PE, Dorey F J, et al. Metal-on-meta| hybrid surface arthroplasty: two to six-year follow-up study. J Bone Joint Surg Am, 2004, 86 - A : 28 - 39.
  • 6Nevelos J, Shelton JC, Fisher J. Metallugical considerations in the wear of metal-on-metal hip bearings. Hip lnt, 2004, 14 : 1 - 10.
  • 7Chan FW, Bobyn JD, Medley JB, et al. Engineering issues and wear performance of metal on metal hip implants. Clin Orthop Relat Res, 1996, 333: 96- 107.
  • 8Saito S, Ishii T, Mori S, et al. Long-term results of metasul metal- on-metal toal hip arthroplasty. Orthopedics, 2010, 33: 548.
  • 9Daniel J, Pynsent PB, McMinn DJ. Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res, 2004, 422:271 -272.
  • 10Clarke MT, Lee PT, Arora A, et al. Levels of metal ions after amall-and large-diameter metal-on-raetal hip arthroplasty. J Bone Joint Srug Br, 2003, 85:913 -917.

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部