对理想状态下的房间空调器采用卡诺循环进行分析,得出了理想空调器能效比的表达式和理论极限值,并采用简单模型分析了导致空调器能效比远低于理论极限值的原因,针对实际工况给出了提高能效比的一些措施.
An ideal domestic air conditioner is analyzed in this paper using the Carnot cycle,to gain the expression and the limit in theory of its COP,then the causes which make the COP of a real air conditioner is lower than its limit in theory is analyzed with a simply model adopted,at last,several methods are suggested to improve the COP of an real air conditioner.
出处
《湖北工业大学学报》
2011年第1期114-116,120,共4页
Journal of Hubei University of Technology
基金
粤港关键领域重点突破项目(佛山专项):多领域统一建模规范的空调产品数字化研发平台及产业化(2009Z009)
关键词
房间空调器
能效比
卡诺循环
变频
domestic air conditioner
coefficient of performance
Carnot cycle