期刊文献+

Electrochemiluminescent Detection Method for Glyphosate in Soybean on Carbon Fiber-ionic Liquid Paste Electrode

Electrochemiluminescent Detection Method for Glyphosate in Soybean on Carbon Fiber-ionic Liquid Paste Electrode
原文传递
导出
摘要 A carbon fiber paste electrode using ionic liquid as the binder (CFILE) was fabricated. The electrochemical characteristics of the electrode was examined in ferro-/ferricyanide solution and showed better conductivity and reversibility when compared with graphite paste-ionic liquid electrode (GPILE) and a little better than that on the carbon nanotube paste-ionic liquid electrode (CNTILE). Glyphosate (GLY), a pesticide, exhibited excellent catalysis to the oxidation of Ru(bpy)3^2+ on CFILE and brought an obvious enhancement to the electrochemiluminescence (ECL) intensity of Ru(bpy)3^2+ . Based on the catalytic ability of GLY, a simple ECL method for GLY detection had been established. Under optimum conditions, the enhanced ECL intensities were found to had linearly respond to the GLY concentration between 3.0× 10 ^-7 and 3.0× 10 ^- 5mol/L, and the detection limit (S/N=3) was 2.0× 10 ^-7 mol/L. The electrode also showed excellent sensitivity in detecting GLY-spiked soybean samples. The linear range for GLY in soybean samples was 1.0× 10 ^-6-4.0× 10 ^-5 mol/L and the detection limit was 5.0× 10 ^-7 mol/L, equal to 8.45 μg GLY in per gram of soybean. The detection limit in soybean sample was lower than the USA, EU regulation and so on. If the method is coupled with the separation technology, it can be applied to detect the GLY in the contaminated samples. A carbon fiber paste electrode using ionic liquid as the binder (CFILE) was fabricated. The electrochemical characteristics of the electrode was examined in ferro-/ferricyanide solution and showed better conductivity and reversibility when compared with graphite paste-ionic liquid electrode (GPILE) and a little better than that on the carbon nanotube paste-ionic liquid electrode (CNTILE). Glyphosate (GLY), a pesticide, exhibited excellent catalysis to the oxidation of Ru(bpy)3^2+ on CFILE and brought an obvious enhancement to the electrochemiluminescence (ECL) intensity of Ru(bpy)3^2+ . Based on the catalytic ability of GLY, a simple ECL method for GLY detection had been established. Under optimum conditions, the enhanced ECL intensities were found to had linearly respond to the GLY concentration between 3.0× 10 ^-7 and 3.0× 10 ^- 5mol/L, and the detection limit (S/N=3) was 2.0× 10 ^-7 mol/L. The electrode also showed excellent sensitivity in detecting GLY-spiked soybean samples. The linear range for GLY in soybean samples was 1.0× 10 ^-6-4.0× 10 ^-5 mol/L and the detection limit was 5.0× 10 ^-7 mol/L, equal to 8.45 μg GLY in per gram of soybean. The detection limit in soybean sample was lower than the USA, EU regulation and so on. If the method is coupled with the separation technology, it can be applied to detect the GLY in the contaminated samples.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2011年第3期581-586,共6页 中国化学(英文版)
基金 Project supported by the National Natural Science Foundation of China (No. 20905013), the Special Foundation for Young Scientists of Fujian Prov- ince, China (No. 2008F3057 ) and the Science and Technology Project of Putian [No. 2009 S 02 (2)].
关键词 carbon fiber paste electrode ionic liquid LUMINESCENCE GLYPHOSATE carbon fiber paste electrode, ionic liquid, luminescence, glyphosate
  • 相关文献

参考文献33

  • 1Adam, H. Mate. Des. 1997, 18, 349.
  • 2Suzuki, M. Carbon 1994, 32(4), 577.
  • 3Bahl, O. P.; Shen, Z, M.; Lavin, J. G.; Ross, R. A. In Carbon Fibers, Eds: Donnet, J. B.; Wang, T. K.; Rebouillat, S.; Peng, J. C. M., Marcel Dekker, New York, 1998, p. 463.
  • 4Deborah, D. L. C. Carbon Fiber Composites 1994, 116.
  • 5Csoregl, E.; Gorton, L.; Varga, G. M. Anal. Chem. 1994, 66, 3604.
  • 6Gross, E. M.; Pastore, P.; Wightrnan, R. M. J. Phys. Chem. B 2001, 105, 8732.
  • 7Maleki, N.; Safavi, A.; Tajabadi, F. Anal. Chem. 2006, 78, 3820.
  • 8Maciej, G.; Andrzej, L.; Izabela, S. Electrochim. Acta 2006, 51(26), 5567.
  • 9Sun, W.; Yang, M. X.; Jiao, K. Anal. Bioanal. Chem. 2007, 389, 1283.
  • 10Maleki, N.; Safavi, A.; Sedaghati, F.; Tajabadi, F. Anal. Biochem. 2007, 369, 149.