期刊文献+

Ultrasonic Extraction Coupled with Capillary Electrophoresis for the Determination of Azo Dyes in Lipsticks Using Ionic Liquid as Dynamic Coating and Background Electrolyte

Ultrasonic Extraction Coupled with Capillary Electrophoresis for the Determination of Azo Dyes in Lipsticks Using Ionic Liquid as Dynamic Coating and Background Electrolyte
原文传递
导出
摘要 A simple and rapid method based on ultrasonic extraction and capillary electrophoresis using l-butyl-3-methylimidazolium tetrafluoroborate as dynamic coating and background electrolyte was developed. The method was applied to the separation and determination of three azo dyes in two lipsticks. To increase extraction rate and yield, lipstick samples were coated on a glass slide before ultrasonic extraction. The dyes were extracted by ultrasonic extraction for 30 min, and then determined by capillary electrophoresis. Several experimental factors, such as ionic liquid concentration, pH value of background electrolyte and applied voltage, were examined and optimized. Under the optimal conditions, three azo dyes were completely separated within 12 min, and the detection limits for the three azo dyes ranged from 0.33 to 0.88 μg/mL. The recoveries were in the range of 96.8% to 108.8%. A simple and rapid method based on ultrasonic extraction and capillary electrophoresis using l-butyl-3-methylimidazolium tetrafluoroborate as dynamic coating and background electrolyte was developed. The method was applied to the separation and determination of three azo dyes in two lipsticks. To increase extraction rate and yield, lipstick samples were coated on a glass slide before ultrasonic extraction. The dyes were extracted by ultrasonic extraction for 30 min, and then determined by capillary electrophoresis. Several experimental factors, such as ionic liquid concentration, pH value of background electrolyte and applied voltage, were examined and optimized. Under the optimal conditions, three azo dyes were completely separated within 12 min, and the detection limits for the three azo dyes ranged from 0.33 to 0.88 μg/mL. The recoveries were in the range of 96.8% to 108.8%.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2011年第1期147-152,共6页 中国化学(英文版)
关键词 capillary electrophoresis ionic liquids DYES LIPSTICK capillary electrophoresis, ionic liquids, dyes, lipstick
  • 相关文献

参考文献35

  • 1Zhao, X. H.; Lu, Y. E; Hardin, I. Biotechnol. Lett. 2005, 27, 69.
  • 2Zhao, X. H.; Lu, Y. P.; Phillips, D. R.; Hwang, H. M.; Hardin, 1. R. J. Chromatogr. A 2007, 1159, 217.
  • 3Gomathi Devi, L.; Girish Kumar, S.; Mohan Reddy, K.; Munikrishnappa, C. J. Hazard. Mater. 2009, 164, 459.
  • 4Lucas, M. S.; Dias, A. A.; Sampaio, A.; Amaral, C.; Peres, J. A. Water Res. 2007, 41, 1103.
  • 5Pinheiro, H. M.; Touraud, E.; Thomas, O. Dyes Pigm. 2004, 61, 121.
  • 6Bhaskar, M.; Gnanamani, A.; Ganeshjeevan, R. J.; Chandrasekar, R.; Sadulla, S.; Radhakrishnan, G. J. Chromatogr. A 2003, 1018, 117.
  • 7Dossi, N.; Piccin, E.; Bontempelli, G.; Carrilho, E.; Wang, J. Electrophoresis 2007, 28, 4240.
  • 8Sasaki, K.; Sakai, M.; Matusita, K.; Masuda, Y.; Sato, K. Bunseki Kagaku 2008, 57, 833.
  • 9Sahin, S.; Demir, C.; Gtiger, S. Dyes Pigm. 2007, 73, 368.
  • 10Jain, R.; Sharma, N.; Radhapyari, K. J. Appl. Electrochem. 2009, 39, 577.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部