摘要
对一套典型连续重整装置预加氢反应器床层多次出现压力降升高,频繁撇头的情况进行了系统的全面分析,查清了造成撇头操作频繁的主要原因及设计缺陷,并提出了针对性的具体解决方案。
Through a comprehensive analysis of rise of pressure drop in pre-hydrotreater reactor of a con- tinuous catalytic reformer and frequent skimming, the main causes of frequent skimming operations and design defects are found out. Corresponding specific solutions are proposed.
出处
《炼油技术与工程》
CAS
2011年第3期23-28,共6页
Petroleum Refinery Engineering
关键词
预加氢压力降
原因分析
设计缺陷
解决方案
pressure drop of pre-hydrotreater, cause analysis, design defects, solution