摘要 表面等离子体共振(SPR)生物传感器是一种基于物理光学原理的新型生化分析系统。与传统的超速离心、荧光法相比,具有实时检测、无需标记、耗样量少等特点。介绍了SPR生物传感器的基本原理,着重介绍了SPR生物传感器在生命科学,药物残留,疾病诊断以及食品检测中的应用,并对其发展趋势进行了展望。 The surface plasmon resonance(SPR) biosensor is a new bio-chemical analysis system based on the principle of physio-optics. Compared with conventional methods such as ultracentrifugation and fluorescence, it has many advantages such as real-time detection, label-free, minimal sample consumption and so on. The basic principle of SPR biosensor is summarized, especially the application of SPR biosensor in the field of life science, drug residue detection, disease diagnosis and food examination were described, and the development trend is prospected.
作者 王佳 周健
出处 《传感器与微系统》 CSCD 北大核心 2011年第4期1-4,共4页 Transducer and Microsystem Technologies
基金 国家自然科学基金资助项目(20706019 20876052) 教育部新世纪优秀人才支持计划资助项目(NCET-07-0313)
关键词 表面等离子体共振 生物传感器 发展趋势 surface plasmon resonance(SPR) biosensor development trend
  • 相关文献

参考文献13

二级参考文献109

  • 1丁建清,庞作章.SARS病原及实验室检测研究现状[J].职业与健康,2004,20(11):16-18. 被引量:1
  • 2丘立文,汤汉文,王亚娣,廖金娥,郝卫,温坤,何秀敏,车小燕.酶联免疫吸附试验间接抗体夹心检测SARS-CoV抗原方法的建立和应用[J].中华流行病学杂志,2005,26(4):277-281. 被引量:7
  • 3甄亚平,刘红,齐娜,单若明,王巧巧,吴晓东.SARS-CoV抗原化学发光免疫分析法的应用[J].首都医科大学学报,2005,26(3):293-295. 被引量:4
  • 4孙非,刘立侠,金扩世,许守民,金洪涛,金宁一,靳玉琴,刘志屹,张淑芹,黄伟,江禹,万忠海,赵文彬,邹啸环.传染性非典型肺炎限制性内切酶检测方法的研究[J].中华检验医学杂志,2006,29(1):72-73. 被引量:2
  • 5郭继华,刘通神帅.表面等离子体波检测的新技术研究[J].光学学报,1996,16(9):1322-1325. 被引量:9
  • 6INDVK H E, PERSSON B S, CASELUNG M C, et al. Determination of vitamin B12 in milk products and selected foods by optical hiosensor protein-binding assay: Method comparison [J]. J Assoc Off Anal Chem, 2002, 85(1):72-81.
  • 7GERLIE C. Immunochemical detection of salmonella group B, D and E using an optical surface plasmon resonance biosensor[J]. FEMS Microbiology Letters, 2003, 222.. 197-200.
  • 8SHIMUMUR M, NOMUR Y, ZHANG W, et al. Simple and rapid detection method using surface plasmon resonance for dioxins, poly-chlorinatal biphenylx and atrazine[J]. Analytica Chimica Acta, 2001, 434: 223-230.
  • 9FERGUSON J P, BAXTER G A, MCEVOY D G, et al. Detection of streptomycin and dihydrostreptomycin residues in milk, honey and meat samples using an optical biosensor[J]. Analyst, 2002, 127: 951-956.
  • 10McGRATH T, BAXTER A, FERGUSON J, et al. Multi sulfonamide screening in porcine muscle using a surface plasmon resonance biosensor[J]. Analytica Chimica Acta, 2005, 529: 123-127.

共引文献135

同被引文献89

引证文献11

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部