阐述了该机组的结构与特点,提出了一种综合考虑相变材料利用率、空气处理效果满意率和运行费用节省率来确定系统最佳蓄冷量和运行方案的方法;通过经济分析提出了临界附加初投资的概念,可作为是否应该投资的判据;作为算例,对该机组的经济性及其在北京地区的使用效果作了全年模拟分析。
Explains its structure and features, presents a method for determining the optimum
thermal storage and operation programmes on a trade off basis between usage of the phase
change material, effects of air handling and the savings in operation costs; Following an economic
analysis, defines a concept of critical additional initial investment as a measure of the units'
profitability; And provides an annual simulation of the economics and effects when used in Beijing
area.
出处
《暖通空调》
北大核心
1999年第4期8-11,共4页
Heating Ventilating & Air Conditioning
基金
国家自然科学基金
关键词
相变贮能
风机组
经济分析
蓄冷量
蓄冷空调系统
fresh air handling unit with phase change material, economic analysis, critical
additional initial investment, optimum thermal storage